1
Modem-Converter E1-L/S
© 2006 Cronyx
Digital Port (V.35 / RS-530 / RS-232 / X.21) Connector
The HDB44 (female) connector is provided for connection cable to the multistandard
(«-M» version) digital interface port:
Pin.
V.35
RS-530 RS-232 X.21
10
TXD-a TXD-a
TXD
Transmit(A)
25
TXD-b TXD-b
—
Transmit(B)
8
RXD-a RXD-a
RXD
Receive(A)
9
RXD-b RXD-b
—
Receive(B)
6
ETC-a ETC-a
ETC
ETC(A)
7
ETC-b ETC-b
—
ETC(B)
2
TXC-a TXC-a
TXC
SigTiming(A)
3
TXC-b TXC-b
—
SigTiming(B)
5
RXC-a RXC-a
RXC
—
4
RXC-b RXC-b
—
—
17
ERC-a ERC-a
ERC
—
18
ERC-b ERC-b
—
—
14
RTS
RTS-a
RTS
Control(A)
29
—
RTS-b
—
Control(B)
11
DTR
DTR-a
DTR
—
26
—
DTR-b
—
—
13
DSR
DSR-a
DSR
—
28
—
DSR-b
—
—
15
CTS
CTS-a
CTS
—
30
—
CTS-b
—
—
12
CD
CD-a
CD
Indication(A)
27
—
CD-b
—
Indication(B)
1,16
GND
GND
GND
GND
31
SEL-0* SEL-0*
SEL-0* SEL-0
33
SEL-1 SEL-1*
SEL-1
SEL-1*
35
SEL-2 SEL-2
SEL-2* SEL-2
37
SEL-3 SEL-3*
SEL-3* SEL-3*
39
SEL-4* SEL-4
SEL-4
SEL-4
41
SEL-5* SEL-5
SEL-5
SEL-5
43
SEL-6* SEL-6
SEL-6
SEL-6
32
DCE
DCE
DCE
DCE
* - Connect to GND