CRL JACKSON 300 SERIES THIN SLAB FLOOR MOUNTED DOOR CLOSER
05
crlaurence.com | usalum.com
CLOSER INSTALLATION
1. Cut-out a 1'-0" (304.8mm) long x 5 5/8" (142.8mm)
wide x 2 1/4" (57.1mm) deep hole.
2. Place and secure the Cement Case into the
hole using Rockite expanding cement.
3. Insert the Adjustable Mounting Brackets.
4. Place the closer in the case and adjust the screws
on the adjustable brackets to firmly secure the
closer in place.
1'-0" (304.8mm)
5 5/8"
(142.8 mm)
2 1/4"
(57.1 mm)
Cat. No. 202102N
Cement Case
Cat. No. 202120
Mounting Brackets
Cat. No. 20307
Closer Body