40
3.2.1
Typical installation
(Non-contractual picture)
3.2.2
Public AC network or generator
The mains cable enters through a cable gland.
Model
Minimum section of the AC power cable
Residual Current Device 16A
3 x 2.5 mm²
Residual Current Device 32A
3 x 6 mm²
All shore-power units
can operate automatically from single-phase networks of 115
(1)
/230VAC and
50/60Hz.
It is essential to use ferrules with insulating collars for flexible cables in accordance with the installation standards.
NOTE: The residual-current device test button does not work for voltages below 185VAC
(1)
Consult CRISTEC for any use at 115VAC 60Hz.
Generators
CRISTEC shore-power units are designed to operate from a generator.
Be careful:
In some cases, the generators can produce high over voltages, in particular during start-up
phase. Before connecting the charger, please check its compatibility with the characteristics of the
generator: power, voltage, overvoltage, frequency, current, etc.
It’s highly advised to disconnect the charger from the AC network during the generator starting phase.
Any damage to the charger due to a voltage surge will be excluded from the warranty.