While the system is in the Armed state:
• The Status Indicator Light will be flashing slowly to confirm that the
system is armed, and also serve as a visual deterrent.
• The starter interrupt circuit is engaged.
• Protected zones are being monitored for intrusion attempts.
Should an activation into the alarm condition occur:
• The changing-tone electronic siren will loudly sound.
• The parking and lights will flash.
• The doors will lock,* regardless of their locked or unlocked status. This
feature is unique- if the system detects that a door is opened, it waits until
the door is closed before relocking it, denying the thief reentry.
An activated alarm condition has a duration of 30 seconds (60 is optional)
unless the system is disarmed using the transmitter or the Easy Valet
TM
switch. If all protected zones are secure at the end of the alarm condition, the
system will stop and rearm automatically, ready to detect another entry
attempt. If a protected zone is still violated at the end of the alarm condition,
the system will reactivate for up to two additional alarm cycles. After the
third alarm cycle the system will automatically rearm and bypass the open
zone until that zone returns to a normal “non-violated” state.
• Once the system resets after it has been activated, upon disarming the
audible and visual confirmation will change to indicate the activation.
This is the “Activation Alert”, which is explained on page 10.
SYSTEM ARMED & ACTIVATED
There are three methods of Disarming the security system:
1- The first method is to press and release the transmitter’s Large Upper
Button to disarm the system. This is the normal “daily use” method.
2- The second method is to press and release twice within 5 seconds the
transmitter’s Small Middle Button. This is “silent Disarming”.
3- The third method is for emergencies, should the transmitter become lost
or inoperable. This is the “Emergency Override”, and uses the ignition
key and Valet Switch.
DISARMING THE SYSTEM
* An optional doorlock interface must be installed
Page 7
THE PARKING LIGHTS
WILL FLASH:
ONCE TO
CONFIRM
DISARMING
1
2
THE DOORS WILL UNLOCK*
To Disarm the System:
Press & Release the Large Upper Button
THE PARKING LIGHTS
WILL FLASH:
ONCE TO
CONFIRM
DISARMING
THE SIREN WILL CHIRP
ONCE TO CONFIRM
DISARMING
Upon Disarming:
• The siren will chirp once (or three times if an alarm activation occurred)
unless the silent disarming procedure is followed.
• The parking lights will flash once (then, if programmed, illuminate for
30 seconds or until the vehicle’s ignition is turned on). Please note that
an option is having the interior lights also illuminate. Please consult
your installing dealer.
• The doors will unlock, either all doors or driver’s door only.*
• The starter interrupt will disengage.
• The Status Indicator Light will show one of these features or conditions:
-Flashing rapidly = Automatic Rearming feature is in progress.
-Off = System disarmed (Automatic Rearming feature not selected).
-Flash /Pause = Indicates violated zone if system has been activated.
THE DOORS WILL UNLOCK*
To Silently Disarm the System:
First Press & Release the Small Middle Button, then
Press & Release the Small Middle Button again
REMOTE DISARMING BY TRANSMITTER
Safety Disarm Feature
:
Pressing and releasing the Large Upper Button while the system is
activated into the alarm condition will disarm the system, but the doors will
remain locked. This is the “Safety Disarm” feature, which allows the ve-
hicle to remain secure, even though an activated system has been disarmed.
Page 8
* An optional doorlock interface, in either standard form or driver’s
door priority form, must be installed