Crestron
GLPPA-REMOTE-USER
User Remote for GLPP Systems
Operations Guide
Crestron Electronics, Inc.
Operations Guide
15 Volvo Drive
DOC. 7217B
Rockleigh, NJ 07647
(2031705)
Tel: 888.CRESTRON
08.13
Fax: 201.767.7576
Specifications subject to
www.crestron.com
change without notice.
Further Inquiries
To locate specific information or resolve questions after
reviewing this guide, contact Crestron's True Blue Support at
1-888-CRESTRON [1-888-273-7876] or, for assistance within
a particular geographic region, refer to the listing of Crestron
world wide offices at www.crestron.com/offices.
To post a question about Crestron products, log onto
Crestron's Online Help at www.crestron.com/onlinehelp.
First-time users must establish a user account to fully benefit
from all available features.
Future Updates
As Crestron improves functions, adds new features, and
extends the capabilities of the GLPPA-REMOTE-USER units,
additional information may be made available as manual
updates. These updates are solely electronic and serve as
intermediary supplements prior to the release of a complete
technical documentation revision.
Check the Crestron Web site periodically for manual update
availability and its relevance. Updates are identified as an
“Addendum” in the Download column.
REMOTE COMMANDS
Commands for the GLPPA-REMOTE-USER are listed in the following table.
MASTER ON/OFF
If any load is on, this button turns all loads off. Otherwise all
loads turn on to 100%.
MASTER RAISE
All loads that are on, at any level, begin to raise. Loads that are
off stay off.
MASTER LOWER
All loads that are on, at any level, begin to lower to 1%. They do
not lower to off.
LOADS 1–3 ON/OFF
Toggles the load between off and 100%.
LOADS 1–3 RAISE
Raises the load level. This turns the load on if it is off.
LOADS 1–3 LOWER
Lowers the load level. The load stops at 1%. If the lower
command continues for another 2 seconds, the load turns off.
COMMANDS
DESCRIPTION
ON
Turns the loads on.
OFF
Turns the loads off.
SCENE 1–8
Toggles the loads according to the programmed settings for
scenes 1 through 8. "Scene 1" enables daylighting.
EDIT SCENES USING USER REMOTE
As of the date of manufacture, the GLPPA-REMOTE-USER
has been tested and found to comply with specifications for
CE marking and standards per EMC and Radiocommunica-
tions Compliance Labelling.
The Crestron
®
GLPPA-REMOTE-USER is a
compact IR wireless remote designed
specifically for the user of a Crestron Green
Light
®
Power Pack (GLPP)—a room
controller that communicates with
photocells, occupancy sensors, and control
stations to automatically control lighting in
any room. Operating on two (2) AAA
batteries (included), the
GLPPA-REMOTE-USER provides buttons
for operating the GLPP.
DESCRIPTION
GLPPA-REMOTE-USER Physical View
Use the GLPPA-REMOTE-USER to change the default scene settings for scenes 1
through 8.
1. U
se
LOAD 1 ON/OFF
,
LOAD 1 ,
or
LOAD 1
buttons to set load to the desired
level. Repeat this process for the other connected loads. Alternatively, use
MASTER
ON/OFF
,
MASTER ,
or
MASTER
buttons to set the levels of all connected loads.
2. Press and hold the appropriate
SCENE 1
through
SCENE 8
button for 2 seconds to
save the scene. The GLPP beeps when the scene is saved.
NOTE
: Only "Scene 1" enables daylighting.
3. Repea
t the steps above for all scenes that need
to be configured.