background image

 

Standby Timeout 

On the FT-TSC600 Setup screen, tap Standby Timeout to display the Standby Timeout 
screen. 

Standby Timeout Screen 

 

The Standby Timeout screen provides controls to adjust standby timeout from 0 to 120 
minutes. 

Diagnostics 

On the FT-TSC600 Setup screen, tap Diagnostics to display the Diagnostics screen. 

Diagnostics Screen 

 

The Diagnostics screen displays the available memory and contains controls to show 

hardware configurations, show Cresnet

®

 devices (to display all devices on the Cresnet 

network), show the message log, show the last reboot message, and show performance 
statistics. In addition, there are controls to open various test screens and to initiate touch 
screen calibration. These are explained in the sections that follow. 

Supplemental Guide – DOC. 7593C 

FT-TSC600: FlipTop Touch Screen Control System  

  9 

Содержание FT-TSC600 FlipTop

Страница 1: ...FT TSC600 FlipTop Touch Screen Control System Supplemental Guide Crestron Electronics Inc ...

Страница 2: ...ed at patents crestron com Crestron the Crestron logo 3 Series Cresnet Crestron Toolbox FlipTop and Rava are either trademarks or registered trademarks of Crestron Electronics Inc in the United States and or other countries Internet Explorer is either a trademark or registered trademark of Microsoft Corporation in the United States and or other countries Other trademarks registered trademarks and ...

Страница 3: ... Ethernet Parameters 4 Edit the Advanced Settings 4 Edit the Ethernet Diagnostics 6 Edit the MyCrestron Dynamic DNS Settings 7 Audio Setup 7 Display Setup 8 Application Setup 8 Standby Timeout 9 Diagnostics 9 Keypad Test 10 Touch Test 10 RAVA 11 Test Patterns 11 Calibrate 11 About 12 Save Edit 12 Supplemental Guide DOC 7593C Contents i ...

Страница 4: ......

Страница 5: ...Screen to Enter Setup The setup screens enable basic configuration prior to regular operation of the touch screen During regular operation of the touch screen there are two ways to access the setup screens 1 Place a button on the project main page and assign the reserved join number 17242 that accesses the setup screens 2 Press hard keys 1 2 3 and 4 to the right of the touch screen display in sequ...

Страница 6: ...ed in the following pages of this guide Configure the FT TSC600 Ethernet Setup On the FT TSC600 Setup screen tap Ethernet Setup to display the Ethernet Setup screen Ethernet Setup Screen The Ethernet Setup screen displays current settings such as whether DHCP is on or off the touch screen s hostname and its IP address This screen also contains a link indicator to show the status of the Ethernet co...

Страница 7: ...cel to return to the previous screen Edit the IP Address To edit the IP address tap Edit The Edit IP Address screen opens Edit IP Address Screen Use the keyboard to enter the new IP address Tap Clear to remove a previous entry Backspace to delete the last digit Enter to save a new entry or Cancel to return to the previous screen Supplemental Guide DOC 7593C FT TSC600 FlipTop Touch Screen Control S...

Страница 8: ...rmation After all new settings have been entered tap Reboot at the bottom of the Ethernet Setup screen to reboot the touch screen so the new settings can take effect Edit the Advanced Settings Tap Advanced Settings to display the Advanced Ethernet Setup screen Advanced Ethernet Setup Screen The Advanced Ethernet Setup screen provides controls for enabling or disabling SSL Secure Sockets Layer and ...

Страница 9: ... addresses of DNS Domain Name System registered computers on the network To add a server s IP address tap New to open an on screen keyboard Use the keyboard to enter the IP address of the new DNS server Tap Clear to remove a previous entry Backspace to delete the last digit Enter to save a new entry or Cancel to return to the previous screen On the Advanced Ethernet Setup screen tap the ellipsis a...

Страница 10: ... to verify connection to the router The screen displays a Passed message to show successful connection Tap Ping Crestron com to verify connection to an external DNS server Tap Who to display a list of devices connected to the PC via the Ethernet connection These devices may be Crestron Ethernet devices third party Ethernet devices or PCs including any PC using Crestron Toolbox to connect to the pr...

Страница 11: ...enter the domain and password tap Edit Then tap Register This System Audio Setup On the FT TSC600 Setup screen tap Audio Setup to display the Audio Setup screen Audio Setup Screen The Audio Setup screen provides controls for muting or unmuting the audio adjusting levels for both the master volume and the media volume and playing a test wav file The Media Volume controls adjust the H 264 streaming ...

Страница 12: ...Application Setup screen Application Setup Screen Tap Register to enable the user program to load when the touch screen boots The control text changes to Unregister Tap Unregister to prevent the program from loading when the touch screen boots The control text reverts to Register Tap Start to start the program The control text changes to Stop Tap Stop to stop the program The control text reverts t...

Страница 13: ...screen Diagnostics Screen The Diagnostics screen displays the available memory and contains controls to show hardware configurations show Cresnet devices to display all devices on the Cresnet network show the message log show the last reboot message and show performance statistics In addition there are controls to open various test screens and to initiate touch screen calibration These are explain...

Страница 14: ...unction of the screen When a location button is tapped its indicator on the screen lights This screen also contains a Calibrate button to initiate touch screen calibration During touch screen calibration a crosshair appears at the center of the screen Tap the center of the crosshair which then moves to the upper left part of the screen Tap the center of the crosshair and it moves to another part o...

Страница 15: ... work there is an issue with the settings Test Patterns On the Diagnostics screen tap Test Patterns to display the Test Patterns screen Test Patterns Screen The Test Patterns screen contains buttons for selecting the different available test patterns Display Color Bars Display Vertical Lines Display Gray Scale Display Grid Pattern and Display Test Pattern Calibrate On the Diagnostics screen tap Ca...

Страница 16: ...information about the firmware in the unit Tap Show Details to display more information About Screen Details Save Edit On the FT TSC600 Setup screen tap Save Exit to save all settings exit the setup screens and return to the main project 12 FT TSC600 FlipTop Touch Screen Control System Supplemental Guide DOC 7593C ...

Страница 17: ...This page is intentionally left blank Supplemental Guide DOC 7593C FT TSC600 FlipTop Touch Screen Control System 13 ...

Страница 18: ...Crestron Electronics Inc Supplemental Guide DOC 7593C 15 Volvo Drive Rockleigh NJ 07647 2038115 Tel 888 CRESTRON 04 15 Fax 201 767 7576 Specifications subject to www crestron com change without notice ...