DigitalMedia™ CAT Receiver
Crestron
DM-RX1-1G
2.
Refer to the following table for the D and M terminal block pinouts.
D and M Terminal Block(s)
1 2 3 4 5 6 7 8
PIN #
WIRE COLOR
PIN #
WIRE COLOR
1
Brown
5 Green
2
White/Brown
6
White/Green
3 Orange 7 Blue
4
White/Orange
8
White/Blue
3.
For DigitalMedia CAT wiring, use DM-CBL DigitalMedia Cable. Up to two DM
Repeaters, model DM-DR (sold separately) may be required. Refer to the latest
version of the Crestron DigitalMedia Design Guide (Doc. 4789) for complete
wiring guidelines.
4.
Refer to the following table for the G B A 24 connector pinouts.
G B A 24 Terminal Block
G B A 24
PIN #
SIGNAL
DESCRIPTION
WIRE COLOR
G
Ground
DC Ground
Black and Ground
B
DMNet-
DMNet
Gray
A DMNet+
DMNet
Orange
24
24V DC
DC Power
Red
5.
DMNet wiring is not compatible with Cresnet wiring. DMNet wiring cannot be
daisy chained.
6.
A grounding lead is provided for connection to earth ground (building steel). This
ground connection is recommended to provide a common ground reference for
signals provided to the DM-RX1-1G, and to reduce the incidence of possible
damage to the unit from static discharge.
12
•
DM
®
CAT Receiver: DM-RX1-1G
Operations & Installation Guide – DOC. 6969B
Содержание DM-RX1-1G
Страница 1: ...Crestron DM RX1 1G WallPlateDigitalMedia CATReceiver Operations Installation Guide...