*Connection to a 24VDC power supply is not required when PoE is used to power the USB
extender or when the DM-NUX-L2-1G is connected to the Host device.

NOTE: The CONFIG jack on the USB endpoint is reserved for factory
use only.

Mount the USB Endpoint

1. Place the USB endpoint into the electrical box.

2. Use two included 6-32 x 1/4 in. pan-head mounting screws to attach

the USB endpoint to the electrical box.

3. Attach a faceplate (not included) to the USB endpoint.

3

DM-NUX-L2-1G and DM-NUX-R2-1G

Quick Start

DM NUX USB over Network Wall Plates with Routing

Содержание DM-NUX-L2-1G

Страница 1: ... signals are transported over the local network and managed through a Crestron control system The DM NUX L2 1G and DM NUX R2 1G are functionally similar For simplicity within this guide the term USB endpoint is used except where noted The USB endpoints are also compatible with the USB over Ethernet Extenders with Routing DM NUX L2 and DM NUX R2 In the Box 1 DM NUX L2 1G1 or DM NUX R2 1G1 Additiona...

Страница 2: ...ter shielded twisted pair STP cable through the opening on the top of the electrical box NOTES l To comply with the European Directive CE Crestron recommends using high quality solid core CAT5e or better shielded twisted pair STP cable l The CAT5e or better cable must have a straight through conductor configuration with no crossovers and must be terminated with 8 conductor RJ45 connectors at both ...

Страница 3: ... the USB endpoint is reserved for factory use only Mount the USB Endpoint 1 Place the USB endpoint into the electrical box 2 Use two included 6 32 x 1 4 in pan head mounting screws to attach the USB endpoint to the electrical box 3 Attach a faceplate not included to the USB endpoint 3 DM NUX L2 1G and DM NUX R2 1G Quick Start DM NUX USB over Network Wall Plates with Routing ...

Страница 4: ...network Check the Installation Check that the ACT HOST LINK and PWR LEDs light on both the DM NUX L2 1G and the DM NUX R2 1G If the HOST or LINK LEDs do not light then the cabling between the USB endpoints and the network may be installed incorrectly or may be defective The following table describes the behavior of the LEDs on the front panel of the USB endpoint LED Color Description ACT Flashing ...

Страница 5: ...1 Ensure that the DM NUX L2 1G is directly connected to the DM NUX R2 1G 2 On the DM NUX L2 1G press and hold the PAIR button for less than 10 seconds The LINK LED on the front panel of the endpoint starts flashing green fast indicating that the endpoint is in Pairing mode NOTE Press and hold the PAIR button a second time for less than 10 seconds to cancel Pairing mode 3 Within 10 minutes of activ...

Страница 6: ...switches exist on different subnets Ensure that network switches can communicate with each other and are on the same subnet Network switch is blocking traffic from the extenders Ensure that traffic is not blocked due to MAC address or traffic patterns If the problem persists contact the network administrator The LINK LED is blinking slowly The DM NUX L2 1G and DM NUX R2 1G are paired with each oth...

Страница 7: ... warranty The specific patents that cover Crestron products are listed at www crestron com legal patents Certain Crestron products contain open source software For specific information visit www crestron com opensource Crestron the Crestron logo DigitalMedia and DM 8G are either trademarks or registered trademarks of Crestron Electronics Inc in the United States and or other countries macOS is eit...