This guide explains how to use the DM-CONN-ULTRA-PLUG-20
Connectors with the DM-CRIMP-ULTRA-PLUG Termination Tool, both
sold separately.

The Crestron®

DM-CONN-ULTRA-PLUG-20

is a shielded CAT6a RJ-45

plug designed for use with the

DM-CONN-ULTRA-RECP-20/50

and the

DM-CONN-ULTRA-RECP-XA-20

(45-Degree Angled) Connectors (sold

separately) for DigitalMedia™ Ultra Cables (

DM-CBL-8G

and

DM-CBL-ULTRA

, sold separately).

The termination tool (

DM-CRIMP-ULTRA-PLUG

) is required to terminate

the DM-CONN-ULTRA-PLUG-20.

The DM-CONN-ULTRA-PLUG-20 ships in packs of 20. Each pack includes
a plug body, the optional boot and latch protector, and the termination
module to be used with the termination tool.

For simplicity in this guide, the plug is referred to as the
DM-CONN-ULTRA-PLUG.

Prepare the Cable for Termination

Flush cutters, a flat screwdriver, a jacket stripper, and the termination
tool (DM-CRIMP-ULTRA-PLUG) are not included and are required for
cable termination.

Prepare DM-CBL-8G Cable

CAUTION:

Do not nick the foil shield or the insulation of the wires.

1. Strip the outer jacket of the cable about 2 in. from the end of the cable.

2. Fold back the foil so that it lies over the cable jacket.

3. Fold back the drain wire and wrap it around the foil shield.

1

DM-CONN-ULTRA-PLUG-20 & Termination Tool

Connectors and Termination Tool for DigitalMedia™ Ultra Cables

Содержание DigitalMedia DM-CONN-ULTRA-PLUG-20

Страница 1: ...ug body the optional boot and latch protector and the termination module to be used with the termination tool For simplicity in this guide the plug is referred to as the DM CONN ULTRA PLUG Prepare the...

Страница 2: ...end of the cable 2 Fold back the braid shield so that it lies over the cable jacket 3 Remove the foil shield from each of the four twisted pairs 4 Gently pull the braid shield away from the cable Twis...

Страница 3: ...G or the DM CBL ULTRA into the termination module and then pull the wires until the braid or foil shield is seated immediately below the wire channels NOTE Ensure that any braided or foil shield is fo...

Страница 4: ...s cut the wires flush with the edge of the channels 7 Trim the excess DM CBL ULTRA braid shield or the excess DM CBL 8G drain and foil shield 8 Attach the plug body onto the termination module matchin...

Страница 5: ...he DM CONN ULTRA PLUG 3 If using the optional boot engage both the top and bottom latches Dismantle the DM CONN ULTRA PLUG Dismantling the DM CONN ULTRA PLUG connector requires removing the boot and t...

Страница 6: ...amp and remove laced conductors NOTE A probe pic can be used to remove the laced conductors Visit the Product Page Scan the QR code to visit the product page DM CONN ULTRA PLUG 20 www crestron com mod...

Страница 7: ...ww crestron com warranty The specific patents that cover Crestron products are listed at www crestron com legal patents Certain Crestron products contain open source software For specific information...

Отзывы: