DO
GUIDE
C2N(I)-AMP-6X100
6 Room + 2 Room Audio System
DO
Check the Box
QUANTITY PRODUCT
PART NUMBER
2
Metal, Bracket, Ear, 2U
2034434
1
Power Cord, 3-Prong
2001134
2
Connector, 4-
P
in
2003576
6
Connector, 4-
P
in,
R
ight-
A
ngle
2003584
6
Screw, 06-32, 5/16" L, Flat, Phillips
2007223
1
Label, Filler Strip, Cardstock, 11.9" x 0.4"
4520506
1
Label, Filler Strip, Cardstock, 7.9" x 0.4"
4520508
1
Label, Custom, Identification
4509950
1
Safety Instructions
2018589
DO
Make Connections
Make the necessary connections as called out in the diagram below. Connect power last.
DO
Install the Device
The C2N(I)-AMP-6X100 can be mounted in a rack or stacked with other equipment. Two “ears” are provided with the C2N(I)-AMP-6X100 so that the unit can
be rack mounted. These ears must be installed prior to mounting. The only tool required is a #1 or #2 Phillips screwdriver.
WARNING:
To prevent bodily injury when mounting or servicing this unit in a rack, observe the following guidelines:
• When mounting this unit in a partially filled rack, load the rack from the bottom to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before mounting or servicing the unit in the rack.
NOTE:
Observe the following guidelines when installing equipment in a rack:
• Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack
environment may be greater than room ambient temperature. Therefore, consideration should be given to installing the equipment in an environment
compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
• Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not
compromised.
• Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical
loading.
• Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the
circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when
addressing this concern.
• Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other
than direct connections to the branch circuit (e.g., use of power strips)
.
NOTE:
If rack mounting is not required, rubber feet are provided for tabletop mounting or stacking. Apply the feet near the corner edges on the underside of
the unit.
CAUTION:
To prevent equipment damage, use only the rack ears Crestron
®
provides for this device.
ANALOG SOURCES (OUT):
To Additional Amplifiers
ANALOG SOURCES (IN):
From Source Devices
LINE OUTPUTS:
To Additional Amplifiers
(Mirrors Outputs 5 and 6)
ROOM OUTPUTS:
To Additional Amplifiers
NET:
To Cresnet
®
Network
LAN:
10BASE-T/100BASE-TX
Ethernet to LAN
POWER:
From Line Voltage
Ground
SPEAKER OUTPUTS:
To Loudspeakers
NON-BRIDGE
L+ - + -R
+
-+ -
LEFT RIGHT