INSTALLATION INSTRUCTIONS

INSTRUCTIONS D’INSTALLATION

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should 

always be followed including the following:

READ AND FOLLOW ALL SAFETY 

INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 

- RISQUE DE CHOC - COUPER L’ALIMENTATION 

AVANT L’INSTALLATION

2.  CAUTION

 

– Installation and servicing should be performed by 

qualified personnel only. De-energize before opening.

ATTENTION

 

– L’installation et l’entretien doivent être effectués 

par du personnel qualifié seulement. Mettre hors tension avant 

l’ouverture

3.  To reduce the risk of electric shock, disconnect both standard and emergency power supplies and converter connector of the 

emergency driver before servicing.

Pour réduire le risque de décharge électrique, vous devez déconnecter à la fois le disjoncteur divisionnaire ou les fusibles et les 

alimentations d’urgence avant l’entretien.

4.  Do not use outdoors.

Ne pas utiliser à l’extérieur.

5.  Do not let power supply cords touch hot surfaces.

Ne laissez pas les cordons d’alimentation toucher les surfaces chaudes.

6.  Do not mount near gas or electric heaters.

Ne montez PAS près des appareils de chauffage de gaz ou électriques.

7.  Do not use this equipment for other than intended use.

8. 

Equipment should be mounted in locations and heights where it will not readily be subjected to tampering by unauthorized 

personnel.

L’équipement doit être monté dans des endroits et à des hauteurs où il ne sera pas soumis à des altérations par des personnes 

non autorisées.

9.  The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.

L’utilisation d’accessoires non recommandés par le fabricant peut causer une situation dangereuse. 

10.  Max. mounting height: 20 ft.

Hauteur de montage max.: 10.

11. 

Do not handle energized module with wet hands or when standing on wet or damp surfaces, or in water.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

NOTES:

 

•  DO NOT handle the Luminaire by the light bars. See 

Figure 7

 on the back page for required handling locations.

•  Products with the -EB suffix are provided with a factory-installed emergency lighting LED battery pack and are eligible to serve as part of a 

facility’s emergency lighting system in accordance with ANSI/NFPA 101 and Article 700 of ANSI/NFPA 70.

•  When mounted at or below 20ft, -EB products will provide the required 1 foot-candle of illuminance on the floor.

Max Rated Ambient

Fixture Size

Suspended 18"

Surface Mount

18L

55C

45°C

24L

55C

45°C

Содержание LXB Series

Страница 1: ...not mount near gas or electric heaters Ne montez PAS près des appareils de chauffage de gaz ou électriques 7 Do not use this equipment for other than intended use 8 Equipment should be mounted in locations and heights where it will not readily be subjected to tampering by unauthorized personnel L équipement doit être monté dans des endroits et à des hauteurs où il ne sera pas soumis à des altérati...

Страница 2: ...ecure cover in place using screw removed in Step 4 PENDANT INSTALLATION STEP 1 Mount the Pendant Mount Box to the mounting location by attaching the customer supplied threaded suspension conduit along with the 2 customer supplied locknuts one for the inside of the Pendant Mount Box and one for the outside to the Pendant Mount Box STEP 2 Remove the Wire Access Cover from the top of the luminaire by...

Страница 3: ...ference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to corr...

Страница 4: ...naire lead to the neutral supply lead d Connect ground bare or green yellow lead to the incoming ground lead from the conduit or screw the green ground lead to the existing troffer pan if the safety ground is made through the pan on the existing troffer e If 0 1 10V Dimming is used connect the violet lead to the supply positive dimming lead If dimming is not being used ensure to cap off the violet...

Отзывы: