1 of 3
CI317X01R5
Cree Edge™
LED Area and Flood Adjustable Arm Mount
Includes: ARE-EDG-AA, ARE-EDR-AA, FLD-EDG-AA AND FLD-EDR-AA
INSTALLATION INSTRUCTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions
should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. DANGER
- Risk of shock- Disconnect power before installation.
DANGER
– Risque de choc – Couper l’alimentation avant l’installation.
2. This luminaire must be installed in accordance with the NEC or your local
electrical code. If you are not familiar with these codes and requirements,
consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code électrique local.
Si vous n’êtes pas familier avec ces codes et ces exigences, veuillez contacter
un électricien qualifié.
3. STRAIN RELIEF IS REQUIRED for electrical connections on
2" (51 mm) adjustable fitter mounts at heights of 25'
(7.6 m) and above. Tie a knot in the supply wires above the hole
in the lower fitter wiring compartment to reduce the strain on the
connections. Make sure knot will not slip through hole.
SOUCHE DE DÉTENTE EST NÉCESSAIRE pour le branchement électrique sur
2”(51 mm) montures Ajusteurs réglable en hauteur de 25 pi (7,6 m) et plus. Faire
un noeud dans les fils d’alimentation au-dessus du trou dans le compartiment
de câblage de inférieure installateur pour réduire la pression exercée sur
les connexions. Assurez-vous que le noeud ne glisse pas dans le trou.
4.
When handling, hold fixture on sides to prevent damage to the top screen or
LED’s
5. Take care to keep the LED lenses clean during installation.
6. The supply wiring (to be supplied by customer) may be connected
either in the fitter compartment or directly to the terminal strip.
See the appropriate section below for the desired method.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
TO INSTALL:
MOUNTING - WIRE CONNECTIONS IN FITTER
COMPARTMENT
STEP 1:
Remove the splice compartment cover from the lower
fitter.
See
Figure 1 and 3.
STEP 2:
Route the fixture power supply wires, coming
from the terminal strip, into the lower fitter and
assemble the lower fitter onto the upper fitter
using the 3/8" bolt provided. Make sure not to pinch
the O-ring between the fitters. See
Figure 1 and 3.
STEP 3:
Route the supply wires into the lower fitter wiring
compartment by puncturing the internal seal with
the supply wires.
STEP 4:
Strain relief is required for electrical connections
on the adjustable fitter mount for mount heights
of 25' (7.6 m) and higher. Tie a knot in the
supply wires above the hole in the lower fitter
wiring compartment to reduce the strain on the
connections. Make sure knot will not slip through
hole.
1
2
Upper Fitter
Set Screws
Lower Fitter
Splice Compartment Cover
• Prior to installation, store luminaire in a dry location
protected from rain, dust, and outdoor environment.
If equipped with a photocell receptacle, remove the
protective cover only if immediately replacing with a
suitable photocell, shorting cap, or other compatible
device. The protective socket cover is not intended
to remain in place after installation. Do NOT leave
receptacle open to environmental elements. Luminaires
with a top-mounted photocell receptacle should not be
installed in an up-light position or at a tilt greater than 45