background image

1 of 2

CI088X02R3_B

THE EDGE

®

 

LED Area Post Top Mount

Includes: ARE-EDG-R3, R4

INSTALLATION INSTRUCTIONS

INSTRUCTIONS D’INSTALLATION

TO INSTALL:

MOUNTING TO 3" ROUND TENON

STEP 1:

Remove hub cover and pull fixture supply wires through top of 
hub. See 

Figure 1

.

STEP 2: 

Slip fixture hub over pole tenon and route supply wires 
through the top of the hub.

STEP 3: 

Tenon mounted fixtures are provided with a 3” (77 mm) long 
rod. After feeding power supply cord up through round hub, 
wrap the upper portion of the cord around the rod and tie into 
knot. The rod should then be diagonally inserted into round 
hub, and positioned so that it rests on the circular inside 
edge of hub. See 

Figure 3.

 The rod, being held in the hub, will 

support the full weight of the power cord running down the 
pole, and will relieve any pressure on the connections made 
inside the hub.

STEP 4: 

Secure the fixture by alternating fastening of eight 3/8” 
cup point set screws. See 

Figure 2.

 Set screws should be 

tightened to 
120 in-lbs. (13 N-m)

STEP 5:

Make wiring connections per 

Electrical Connection

 section. 

STEP 6: 

Replace hub cover that was removed in Step 1 after 
completing electrical connections.

DIRECT MOUNT TO 4" SQUARE STEEL SHAFT

STEP 1:

Remove hub cover and pull fixture supply wires through top of 
hub. See 

Figure 4 

on page 2.

1

2

Hub Cover

3/8” Set Screws

NOTES:

1.  This carton contains complete fixture and fitter assembly.
2.  Tenon mount luminaires used on aluminum, reinforced 

fiberglass, or fiberglass poles must be mounted on 3" (77 
mm) O.D. tenons.

3.  Make electrical connections to input power supply with 

appropriately sized (10-18 gauge) wire nuts. Larger wire 
nuts will cause interference problems on tenon mount 
luminaires.

IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be 

followed including the following:

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

1.  DANGER

- Risk of shock- Disconnect power before installation.

DANGER

 – Risque de choc – Couper l’alimentation avant 

l’installation.

2.  This luminaire must be installed in accordance with the NEC 

or your local electrical code. If you are not familiar with these 

codes and requirements, consult a qualified electrician. 

Ce produit doit être installé conformément à NEC ou votre code 

électrique local. Si vous n’êtes pas familier avec ces codes et 

ces exigences, veuillez contacter un électricien qualifié. 

SAVE THESE INSTRUCTIONS 

FOR FUTURE REFERENCE

Отзывы: