Credence CTE701A Скачать руководство пользователя страница 1

Workstation
Monitor
Checker

User’s Guide

Credence Technologies, Inc.

Model CTE701A

Credence Technologies, Inc.

3601-A Caldwell Dr.

Soquel, CA 95073 U.S.A.

Tel. 831-459-7488  FAX 831-427-3513

www.credencetech.com

© 2006 Credence Technologies, Inc.

Ground Masteris registered trademark
of Credence Technologies, Inc.
Patent Pending.  Made in U.S.A.

PUB01907

Limited Warranty

Credence Technologies, Inc. warrants Worskstation Monitor Checker to be free from defects in materials and
workmanship under normal use and service for a period of one (1) year from date of purchase directly from
Credence Technologies, Inc., or from its authorized distributors.  This warranty extends only to the original
purchaser.  This warranty shall not apply to any product or part of it  which has been subjected to misuse,
neglect, accident or abnormal conditions of operation.   Except to the extent precluded by applicable state
law, Credence Technologies will have no liability for any consequential, incidental, or special damages.

In the event of failure of a product covered by this warranty, Credence Technologies, Inc. will repair a
product returned to authorized distributor or, only if it was purchased directly from Credence Technologies,
Inc., to the manufacturer;  provided the warrantorís examination discloses to the company’s satisfaction
that the product was defective and is qualified for to a warranty claim.  Credence Technologies may, at its
option, replace the product or its components with new or factory-refurbished parts or as whole in lieu of
repair.  With regard to a product returned within one year of its purchase, said repair or replacement will
be made without charge.  If the failure has been caused by misuse, neglect, accident or abnormal
conditions of operation, repairs will be billed at a nominal cost.   Warranty does not cover transportation
costs.

Procedure

q

 Follow instructions in Basics

Basics

Basics

Basics

Basics section

q

 Connect 3.5mm test cable to both the Checker and to Operator jack of

your monitor.

q

 Depress and keep pressed the “Wriststrap” button.  Your monitor should

indicate good connection.

q

 While keeping Pass button, depress and keep pressed Body Voltage

“High” button.

q

 Your monitor should provide indication of excessive body voltage in

each polarity -- positive and negative. If you ordered Checker for WS Aware
with a single terminal for both operators (model CTC061-D), please see
special addendum.  When Body Voltage Low button is depressed, no Body
Voltage indication should be present in the monitor.

Downloaded from 

Elcodis.com

 

electronic components distributor

 

Содержание CTE701A

Страница 1: ...Credence Technologies Inc to the manufacturer provided the warrantorís examination discloses to the company s satisfaction that the product was defective and is qualified for to a warranty claim Credence Technologies may at its option replace the product or its components with new or factory refurbished parts or as whole in lieu of repair With regard to a product returned within one year of its pu...

Страница 2: ... for these resistors then your limit would be 10MOhms 1 MOhm 1MOhm 12 MOhms Limit is set by dip switch 10 10 10 10 10 Switch P Switch P Switch P Switch P Switch Position osition osition osition osition Resistance MOhms Resistance MOhms Resistance MOhms Resistance MOhms Resistance MOhms 10 10 10 10 10 12 0 10 1 Checker by default provides selected resistance plus 1MOhm i e for 12MOhms limit it woul...

Страница 3: ...o set the parameters in accordance with your specification Dissipative ground resistance setting is done using switches 1 4 Switch P Switch P Switch P Switch P Switch Position osition osition osition osition Monitor Alarm Threshold Monitor Alarm Threshold Monitor Alarm Threshold Monitor Alarm Threshold Monitor Alarm Threshold 1 1 1 1 1 2 2 2 2 2 3 3 3 3 3 4 4 4 4 4 1000 MOhms 0 0 0 1 200 MOhms 0 0...

Страница 4: ...s should pass at 9 Ohms and fail at 11 Ohms E M I E M I E M I E M I E M I The checker provides high frequency signal to test EMI detection threshold EMI level is set using dip switch 9 9 9 9 9 The checker provides two different levels of high frequency signal elevated and normal In position 1 the EMI level is elevated in position 0 the level is normal Pressing High push button switch will result i...