Creda Shower SPA Скачать руководство пользователя страница 1

 

16

 

IMPORTANT WARNINGS! 

 

DO NOT SWITCH THE APPLIANCE ON IF YOU SUSPECT IT OF BEING FROZEN. 

WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT. 

 

DO NOT OPERATE THE APPLIANCE IF WATER DISCHARGES FROM THE PRESSURE RELIEF 

VALVE. MAINTENANCE IS REQUIRED BEFORE THE APPLIANCE CAN BE SAFELY USED. 

 

THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN AND 

THE INFIRM) WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,  

OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN 

SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE 

 BY A PERSON RESPONSIBLE FOR THEIR SAFETY. 

 

CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY 

 DO NOT PLAY WITH THE APPLIANCE. 

 

 
 
 
 
 

 

 
 

1.

 

Ensure the electricity and water are turned on to the unit. 

 

2.

 

Press the

 start / stop button “B”

.                                                                                                                                       

This will turn the shower on, the water will flow and the 

neon indicator light will illuminate. It is recommended that 
you do not wholly enter the water flow during this period. 

 

3.

 

Knob “A”

 controls the power selection.                                          

Select “High”, “Med” (Medium) or “Cold”                              

 

The “small bar” indicates knob setting. 

 

4.

 

If the water is not at your 

desired

 showering 

temperature, turn 

knob “C” a small amount 

until you 

reach the desired showering temperature.  

 

Turn clockwise for cooler.                                                        
Turn anti-clockwise for warmer. 

 

5.

 

When you have finished showering, 

press the start / stop button “B” 

again.                                    

The neon indicator will go out             

 

6.

 

Switch off the electricity supply at the ceiling switch or local isolator.   

 

Notes 

 

 

Wait 20 seconds for the temperature to stabilise after each adjustment. 

 

 

The neon indicator light illuminates when the heaters are on and, if the shower has 

been recently used, it may take up to 20 seconds to come on.                                                                 
During this time the water may go from very hot to cold before stabilising. 

 

 

The position of knob “C” will be approximately the same each time the shower is 

used, varying only with incoming water temperature or pressure changes                               
(e.g. you will only need to change from summer to winter). 

 

 

During normal operation, if an overheated water temperature is sensed then the 

heater will switch off and the neon indicator light will go out.                                                                                       
Water will continue to flow and cool down before the heater switches back on again.   

 

 
 

 
 
 
 

 
 
 

 
 
 

 

 

We offer a technical advisory service on the telephone to installers and 
other customers with problems in the field. RING 0844 372 7766 (UK ONLY) 

 (A3) Leaflet No. 567-2151-03b

 

HOW TO USE YOUR 

SHOWER SPA

 (SUMMARY) 

 

 

 

 

 

 
 
 

 

 
 

 
 
 

 

 
 

 
 

 

 
 

 
 
 

 

 
 

 
 
 

 
 

 

IMPORTANT: 

This booklet should be left with the user  

after installation and demonstration

 

SHOWER SPA RANGE

 

ELECTRIC SHOWER 

Installation and User Guide 

 

 

Содержание Shower SPA

Страница 1: ...ired showering temperature Turn clockwise for cooler Turn anti clockwise for warmer 5 When you have finished showering press the start stop button B again The neon indicator will go out 6 Switch off t...

Страница 2: ...ong 1 Self Help What to do if things go wrong 2 Professional Service Creda After Sales Service How your Shower Spa Works Guarantee and Contact Details How to use your Shower Spa Summary Page 3 3 4 6 9...

Страница 3: ...aintained Your shower requires a minimum running pressure of 69kPa 0 7 bar 10 psi At pressures above 69kPa 0 7 bar 10 psi it will minimise temperature fluctuations as detailed above If the water press...

Страница 4: ...installation you may find it convenient to move the flexible pressure relief valve outlet assembly by removing the two securing screws If you do please ensure that they are fully tightened on re assem...

Страница 5: ...gram is shown on page 6 WARNING ENSURE THAT THE MAINS WATER SUPPLY MEETS THE REQUIREMENTS BELOW BEFORE CONTINUING WITH INSTALLATION The heater must be connected to the mains cold water supply This mus...

Страница 6: ...ortant to clean the shower handset by simply rubbing the rubber nozzles or soaking in proprietary lime scale remover and rinsing thoroughly before use actual shower handset not necessarily shown NOTE...

Страница 7: ...if this is used then knob C must be re adjusted 8 The Cold setting of knob A will supply water without any heating 9 Your shower is designed to stabilise temperature changes caused by water pressure f...

Страница 8: ...tions giving a change in water temperature c Check again for leaks and that the holes in the shower handset are not blocked 8 Demonstrate the showers operation to all users 9 ASSEMBLY OF ACCESSORIES D...