Creda Non pumped Скачать руководство пользователя страница 1

 

_

20

_

  

Contact and Commissioning Details

 

 

Model N° : 

Serial N° : 

Installer Contact Name and Address : 

Date Installed : 

 

 

 
 
 
 

GUARANTEE

 

Terms and Conditions for UK (outside UK contact your local distributor)

 

 

We, Applied Energy Products Limited, guarantee this product 

for domestic use only, 

for the period of 24 

months

*

 from the date of purchase. 

 

*

    Months 13 to 24 of your free guarantee are conditional on the registration of your product at the time of purchase.  

Product registration helps us to identify when products are installed, and in what location, in order to facilitate a more 
efficient response to your requests.

 

 
 
 

If the shower is not working p roperly when it is first used, please contact your installer.  They will check that 
the system set up is correct and that the shower has been satisfactorily commissioned. 

 
 

During the period of guarantee, in the unlikely event of a product break -down due to faulty workmanship or 
material defects the product should be returned to Applied Energy Products Ltd for repair  on condition that:- 

 

a)  The appliance has been correctly installed in accordance with our instructions and is being used on the 

supply circuit or voltage printed on the rating plate.  

b)  The appliance has been used in accordance with these instructions and has not been tampered with or  

otherwise been subject to misuse, neglect or accident. 

c)  The appliance has not been taken apart, modified or repaired ex cept by a person authorised by us. 
d)  Evidence of the date of purchase in the form of an invoice or receipt will be required in order to qualify for  

an in-guarantee repair. 

e)  Repair under guarantee has no effect on the expiry date. The guarantee on any exchanged parts or product  

ends when the original guarantee period ends. 

EXCLUSIONS

 

This guarantee 

DOES NOT 

cover damage or defects arising from poor or incorrect installation, improper use or lack of 

maintenance, including build up of limescale. Checking and cleaning of the inlet filters is not covered by this guarantee.  It is 
the responsibility of the installer to check that the installation parameters meet the requirements of the product, and any 
relevant regulations.

 

 
 

We make no guarantees as to repair times. 

 

 

The guarantee applies to a repair or replacement (at our discretion) of the product subject to the conditions above, and 

DOES NOT 

cover compensation for the loss of the product or consequential loss of any kind including the removal, 

refitting and transportation of the product under any within guarantee repair. 
 

 

This guarantee applies to the base unit and remote control only and not to other parts of the installation or product such as: 
Pressure relief devices, sprayheads, hoses, accessories, isolating switches, batteries, electrical cable and/or circuit 
breakers. 

 

This guarantee does not affect your statutory rights. 

 

 

 

 

 
 

Applied Energy Products Ltd. Morley Way, Peterborough.  PE2 9JJ. 

Telephone  01733 456789 

Fax  01733 310606 

 

www.applied-energy.com 

(A3)  567 2194 40A 

 

_

1

_

  

 

 

Installation and User Guide

  

Please leave this guide with the end user (for future reference)

 

 

 

 

Models 

Pumped 

Non pumped 

 

 

Thermostatic Digital 
Mixer Shower 

Electronic Remote Control Mixer Shower

 

 
 
 

This Handbook is for the Installer and User 

 

You must read these instructions prior to installing and 

commissioning the mixer shower 

 

Note to Installer : 

For the benefit of the customer please complete : 
Your contact details and commissioning information on Page 20. 

Содержание Non pumped

Страница 1: ...antee has no effect on the expiry date The guarantee on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS This guarantee DOES NOT cover damage or defects arising f...

Страница 2: ...Contact commissioning details 19 20 Guarantee 20 Symbols Paragraphs marked with this symbol contain important information and recommendations particularly as regards safety Refers to actions that mus...

Страница 3: ...Check water connections are correct Page 5 Wait for heat to recover Ensure stat is adjusted to 65 C FLOW Pulsating water flow Solenoid filter blocked Air lock in pipes Remove and replace solenoid valv...

Страница 4: ...remote control handset sited inside the cubicle If the installation involves working at height ensure that the Working at Height Regulations 2005 are followed This includes ensuring there is Proper la...

Страница 5: ...moisture c Fitting and Plumbing Mark up and fix Decide where to mount the base unit ensuring There is adequate clearance for access around the base unit including connection of the hot and cold and s...

Страница 6: ...hile cleaning isolate the power supply to the base unit Clean the shower remote control using a soft cloth and avoid using abrasive or solvent based cleaning fluid especially on any plated finishes Wa...

Страница 7: ...come from a balanced pressurised supply Diagram of un vented thermal store system High pressure Combi boiler Non Pumped Model only Pressure reducing valves are required if the pressure is above 5 bar...

Страница 8: ...available Flow Decrease Flow Increase Flow display The flow adjustment is from 1 segment to 7 segments Segments 1 2 3 4 5 6 7 Flow Min Flow increases Max Note Installation restrictions and Combi boil...

Страница 9: ...es b Adjusting the temperature and flow Press the Temperature buttons to adjust the temperature Temp Decrease Temp Increase The temperature adjustment is from L low then 1 to 9 then H high Display L 1...

Страница 10: ...If the Reset has not been done in this time then press the Start button again The remote will give a series of long and short bleeps to acknowledge the reset Replace the battery cover including the fi...