background image

Wattage (W) 

Model  with 

controls white 

Model with controls 

silver 

Model  with no 

controls white 

Dimensions 

(mm) 

500 

NPP50 75-773001 

NPP50S 75-773011 

NP50 75-772901 

442 x 430 x 80 

1000 

NPP100 75-773002 

NPP100S 75-773012 

NP100 75-772902 

680 x 430 x 80 

1500 

NPP150 75-773003 

NPP150S 75-773013 

NP150 75-772903 

680 x 430 x 80 

2000 

NPP200 75-773004 

NPP200S 75-773014 

NP200 75-772904 

852 x 430 x 80 

Creda Newera Profile and Profile Plus Panel Heaters

 

Installation and Operating Instructions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

The Newera Profile panel heater range is designed for wall mounting on the wall brackets supplied.  It 
should only be operated when in the upright position as shown in diagram C. 
All models are protected against moisture ingress to IPX4 standard. 
All models, except those with no controls, are fitted with a 7-day digital programmer. 

Installation: 

Before connecting the heater, check that the supply voltage is the same as that stated on the rating label. 
When selecting the position for the heater to be installed, consideration should be given to ensure that there 
are no obstructions closer than the dimensions given in Diagram C.  The bracket for the heater should be 
fitted in accordance with the method detailed in the associated diagrams.  The heater must not be located 
below a socket outlet or connection box. 

Care must be exercised when fitting the heater onto the bracket.  Pressure should only be applied to 
the ends of the heater and not to the grille area. 

The electrical installation must be carried out by a competent electrician and in accordance with the current 
Electrical Wiring Regulations (BS7671) and/or local regulations. 
The heater is fitted with a length of flexible cable for connection to the fixed wiring of the premises via a 
suitable connection box positioned adjacent to the heater. 
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazard. 

A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with 
the wiring rules. 

WARNING – THIS APPLIANCE MUST BE EARTHED 
WARNING – In order to avoid overheating, do not cover the heater. 

Содержание Newera NP100 75-772902

Страница 1: ...r to be installed consideration should be given to ensure that there are no obstructions closer than the dimensions given in Diagram C The bracket for the heater should be fitted in accordance with the method detailed in the associated diagrams The heater must not be located below a socket outlet or connection box Care must be exercised when fitting the heater onto the bracket Pressure should only...

Страница 2: ...o be fitted towards an object obstruction to the left then the bracket should be positioned against the floor and the object obstruction and the wall marked along the right edge of the right upright This is the final position of the left side of the left upright member of the bracket If the heater is required to be fitted towards an object obstruction to the right then the bracket should be positi...

Страница 3: ... or small screwdriver would be a suitable tool Diagram D shows the procedure for releasing the heater from the bracket When replacing the heater on the bracket firstly engage the heater on to the bottom hooks and then press the heater on to the catch It is recommended to press the heater at the ends and not to the grille area No Controls Models 75 772901 75 772902 75 772903 75 772904 and 75 772905...

Страница 4: ...lay to the required setting Press the AFFIRM button and the day display will be flashing and the and button will set the day to the required setting Press the AFFIRM button to end the clock setting and return to the clock display To set the Program firstly press the left button below where it says SETUP on the display Five options will be displayed on the right side of the display These are PROG D...

Отзывы: