Creative PC-68B Скачать руководство пользователя страница 1

User Manual for Wrist Oximeter 

  I          

Instructions to User 

PC-68B Wrist Oximeter is a precision measuring device, 
please read the manual very carefully before using this 
device. Failure to follow these instructions may  cause 
measuring abnormality or damage to the oximeter. 

No part of this manual may be photocopied, reproduced or 
translated into another language without the prior written 
consent. Shenzhen Creative Industry Co., Ltd. reserves the 
right to improve and amend it at any time without prior 
notice. 

Version of This Manual: Ver 1.4 

Revised date: July 26, 2012 

All rights reserved. 

 

 

 

 

3502-2290033

Содержание PC-68B

Страница 1: ...instructions may cause measuring abnormality or damage to the oximeter No part of this manual may be photocopied reproduced or translated into another language without the prior written consent Shenz...

Страница 2: ...Check the device to make sure that there is no visible damage that may affect user s safety and measurement performance When there is obvious damage stop using the device Necessary servicing must be p...

Страница 3: ...ce engineer should not stare at the light emitting components To dispose the device the local law should be followed Attentions Keep the oximeter away from dust vibration corrosive substances explosiv...

Страница 4: ...ximeter is not permitted Refer to related chapter for instructions of cleaning and disinfection Declaration of Conformity The manufacturer hereby declares that this device complies with the following...

Страница 5: ...ERATION 7 3 1 Measuring Operation 7 3 2 Menu Operation 15 3 3 Upload Data 21 3 4 Low Battery Indication 22 4 ADDITIONAL ADVICE FOR OPERATION 23 5 TECHNICAL SPECIFICATIONS 24 6 ACCESSORIES 27 7 REPAIR...

Страница 6: ...ance Figure 1 Front View 1 LCD screen 2 Set key shift display modes confirm the operation etc 3 Scroll key short press move display cursor modify parameter values etc Longtime press choose display alw...

Страница 7: ...Manual for Wrist Oximeter 2 Figure 2 Frontal Side View 4 Buzzer 5 Data interface 6 Wristband Underlay Figure 3 Right Side View 7 SpO2 probe receptacle 1 2 Name and Model Name Wrist Oximeter Model PC...

Страница 8: ...en and stored in the device It is lightweight small in size and easy to carry Color OLED display Perfusion index PI display is available Automatic starts to measure SpO2 and Pulse Rate PR Real time cl...

Страница 9: ...o PC for view and analysis Optional Smart battery power management with low battery indication 1 5 Intended Use This Wrist Oximeter is intended for measuring the pulse rate and functional oxygen satur...

Страница 10: ...ex PR Pulse Rate Pulse rate symbol Low battery voltage Symbol for display always on Memory full Serial number Date of manufacture Authorised representative in the European community Manufacturer inclu...

Страница 11: ...slide it towards the side with SpO2 probe as shown in Figure 4 2 Refer to Figure 4 insert two AAA size batteries into the battery compartment properly in the right direction 3 Replace the cover Remark...

Страница 12: ...ector into SpO2 probe receptacle properly Figure 5 Sp02 Probe Connection 2 Fix the oximeter on your left wrist Figure 6 3 Then hold the probe with its opening towards your index finger The probe shoul...

Страница 13: ...il the fingernail tip rests against the stop at the end of the probe Figure 7 Adjust the finger to be placed evenly on the middle base of the sensor make sure the finger is in the right position If th...

Страница 14: ...screen will be displayed Figure 9A User can read the values and view the waveform from the display screen Figure 9A Default Screen SpO2 SpO2 symbol 99 SpO2 value PR Pulse rate icon 65 Pulse rate valu...

Страница 15: ...t which will be effective during measuring If you choose display always on the symbol for display always on will appear on the screen as shown in Figure 9B Short time press key the display screen can...

Страница 16: ...ual for Wrist Oximeter 11 Figure 9C PI Perfusion index symbol Figure 9D Real Time Clock 12 30 the current time Key Operations Longtime press key menu screen will be displayed refer to section 3 2 for...

Страница 17: ...uring monitoring if the probe is not connected to the oximeter or the probe is off No Signal will be prompted on the screen as shown in Figure 10 Figure 10 No Signal During measuring if the memory is...

Страница 18: ...inserted into the soft rubber of the sensor so the data recording SpO2 and PR values starts simultaneously as well The display is as shown in Figure 9A During measuring if the display mode is not dis...

Страница 19: ...ng time pressing any key will activate the LCD display for measuring default screen or once the finger is inserted in the soft rubber of the sensor the measurement will start and LCD display will be a...

Страница 20: ...terval to record SpO2 and pulse rate data Alarm set SpO2 low limit and pulse rate high low limit Time set current time Trend Review view SpO2 and pulse rate trend graph Delete Data delete all the reco...

Страница 21: ...ructions Short time press key active the option Short time press key select record interval three options 1s 4s and 8s Short time press key confirm the selection Longtime press key back to the menu sc...

Страница 22: ...nge 85 95 default setting 85 PR Lo set pulse rate low limit Setting range 25bpm 99bpm default setting 50bpm PR Hi set pulse rate high limit Setting range 100bpm 250bpm default setting 120bpm Alarm ena...

Страница 23: ...ess key shift cursor circularly Short time press key active the option Short time press key increase numerical value one time Longtime press key increase numerical values continuously Short time press...

Страница 24: ...Settings Date format MM DD YYYY Time format hh mm ss Operation Instructions Short time press key shift cursor circularly Short time press key active the option Short time press key increase numerical...

Страница 25: ...al time of trend graph displayed on this screen Page scroll left right symbol Curves in the middle area Green curve indicate pulse rate trend curve Orange curve indicate SpO2 trend curve Operation Ins...

Страница 26: ...me pressing key all the records will be deleted Figure 17 Delete Records 3 3 Upload Data Before uploading the data to PC please quit from the menu screen if you are doing the setup or trend view opera...

Страница 27: ...Indication If occurs on the screen it indicates battery power is not enough please change batteries If you keep on using after a while when the batteries are exhausted Low Battery indication will be d...

Страница 28: ...ped with a cuff for blood pressure measurement or during venous infusion Do not let anything block the emitting light from device Electrosurgical device interference may affect the measuring accuracy...

Страница 29: ...t 40mA D SpO2 Parameter Specifications Transducer dual wavelength LED Measurement wavelength Red light 663 nm Infrared light 890 nm Maximal optical output power less than 1 5mW maximum average Measuri...

Страница 30: ...I Performance under low perfusion condition The accuracy of SpO2 and PR measurement still meets the specification described above when the modulation amplitude is as low as 0 6 J Resistance to interf...

Страница 31: ...ication The type of protection against electric shock Internally powered equipment The degree of protection against electric shock Type BF applied part The degree of protection against harmful ingress...

Страница 32: ...sories A data cable optional Oximeter Data Manager software optional A Wristband A SpO2 Probe Two batteries AAA A User Manual Quality Certificate Note The accessories are subject to change See the Pac...

Страница 33: ...or wipe it dry Please take out the batteries if the oximeter will not be used for a long time The recommended storage environment of the device ambient temperature 20 C 60 C relative humidity 10 95 at...

Страница 34: ...low level disinfection is required use a 1 10 bleach solution Then surface clean with a damp cloth and dry with a piece of cloth Clean the wristband with soapy water Please detach the wristband from...

Страница 35: ...ed or almost drained 2 The batteries are not inserted properly 3 The device is malfunctioning 1 Change batteries 2 Reinstall batteries 3 Please contact the local service center Fragmental trend curve...

Страница 36: ...ignal 1 The probe is not connected to the oximeter properly 2 The finger is not placed well 3 The probe connector or the probe sensor is broken 1 Connect the probe to the oximeter properly and try aga...

Страница 37: ...t the respiration function it is calculated by the following method SpO2 HbO2 HbO2 Hb 100 HbO2 are the oxyhemoglobins oxygenized hemoglobin Hb are those hemoglobins which release oxygen 2 Principle of...

Страница 38: ...oxygen saturation a percentage of all measured hemoglobin including dysfunctional hemoglobin such as carboxyhemoglobin or metahemoglobin Clinical application of pulse oximeters SpO2 is an important ph...

Страница 39: ...ared heating lamps or direct sunlight Vascular dyes or external used color up product such as nail enamel or color skin care Excessive patient movement Placement of a sensor on an extremity with a blo...

Страница 40: ...ia disease functional lack of HbO2 Pigmentation or abnormal oxyhemoglobin level Abnormal oxyhemoglobin variation Methemoglobin disease Sulfhemoglobinemia or arterial occlusion exists near sensor Obvio...

Страница 41: ...stband Then press the oximeter to make the wristband underlay Fig B stick to the wristband firmly Next follow the Fig C to fix the oximeter well Step 3 The process of wristband disassembly is similar...

Страница 42: ...User Manual for Wrist Oximeter 37...

Отзывы: