background image

User Manual for Spot-Check Monitor

1

CHAPTER 1 OVERVIEW

1.1 Features

Blood pressure, oxygen saturation and pulse rate can be measured;

A wearable device, and convenient to measure;

Small in size, light in weight, easy to carry and operate;

It's intended to use in homes;

The measurement result can be set to the host device via wireless communication.

The measured data can be displayed, stored and manged by APP software installed on the host

device, such as smart phone, tablet, and computer, which can be Android and IOS system.

1.2 Application and Scope

The Spot-Check Monitor is applicable for measuring adult's physiological parameters, such as

non-invasive blood pressure (NIBP), functional oxygen saturation (SpO

2

), and pulse rate (PR).

1.3 Conformation

The Spot-Check Monitor consists of the main unit, functional accessories (cuff, SpO

2

sensor) and the

Содержание PC-101

Страница 1: ...Spot Check Monitor User Instruction Manual ...

Страница 2: ...nd equipment Refer to the respective chapters for details The Manual is published in English and we have the ultimate right to explain the Manual Version of This User Manual Ver1 0 Product expectancy life 5 years not warranty time Issued Date August 29th 2019 Manufacturing date See label on device All rights reserved 3502 2600017 Marks in the Manual Caution must be followed to avoid endangering th...

Страница 3: ...Monitor These instructions describe the operating procedures to be followed strictly Failure to follow these instructions can cause monitoring abnormity equipment damage and personal injury The manufacturer is NOT responsible for the safety reliability and performance issues and any monitoring abnormality personal injury and equipment damage due to user s negligence of the operation instructions T...

Страница 4: ...ot be in use while the battery is charging Check the device accessories including cable and cuff before use Stop use if any damage and aging is found Please check the monitor completely to verify that the accessories can function safely and normally Do NOT use the device under the flammable gas condition or in any environment that may lead to explosion The device is forbidden to be used together w...

Страница 5: ...ents may still have anaphylaxis Do NOT apply to those who have anaphylaxis When disposing of the monitor and its accessories the local law should be followed Contraindication NO Attentions Please store and operate the device in specified temperature humility and atmospheric pressure The excessive ambient environment may affect the measuring result To avoid damaging device if the monitor gets wet p...

Страница 6: ...User Manual for Spot Check Monitor V Note In this Manual long press means press and hold key for about 3 seconds short press means press key for less than 1 second ...

Страница 7: ...ion 1 1 4 Product Name and Model 2 1 5 Working Environment and Power Supply 2 CHAPTER 2 APPEARENCE 4 CHAPTER 3 INSTALLATION AND CONNECTION 7 CHAPTER 4 MEASUREMENT 8 4 1 Blood Pressure Measurement 8 4 2 SpO2 Measurement Optional 12 CHAPTER 5 TECHNICAL SPECIFICATIONS 14 5 1 Blood Pressure Measurement 14 5 2 SpO2 Measurement Optional 14 ...

Страница 8: ... 6 MAINTENANCE AND SERVICE 17 6 1 Technical Maintenance 17 6 1 1 Daily Examination 17 6 1 2 Battery Maintenance 18 6 2 Cleaning and Disinfection of the Main Unit 18 6 3 Cleaning and Disinfection of Accessories 18 6 4 Storage 19 CHAPTER 7 TROUBLESHOOTING 20 CHAPTER 8 ERROR MESSAGE INTERPRETING 21 Warranty Clause 23 Appendix Classification of Blood Pressure Level 24 ...

Страница 9: ...via wireless communication The measured data can be displayed stored and manged by APP software installed on the host device such as smart phone tablet and computer which can be Android and IOS system 1 2 Application and Scope The Spot Check Monitor is applicable for measuring adult s physiological parameters such as non invasive blood pressure NIBP functional oxygen saturation SpO2 and pulse rate...

Страница 10: ... is available and means function is not available Model Configuration Remarks NIBP SpO2 Pulse Rate PC 101 PC 102 1 5 Working Environment and Power Supply 1 Operating temperature 5 40 Operating humility 15 93 Atmospheric pressure 70 0kPa 106 0kPa 2 Power Supply External power supply by AC adapter Input a c 100V 240V with 50 60Hz current 0 5A Output d c 5 0V current 1 2A ...

Страница 11: ...ithium battery with capacity 1000mAh When the device is charging the icon will be displayed on the screen in scroll status when the device is full charged the icon turns to be Normally it will take at least 4 hours to be fully charged to the capacity for use of 120 times of NIBP measurement ...

Страница 12: ...User Manual for Spot Check Monitor 4 CHAPTER 2 APPEARENCE Figure 2 1 Demonstration 1 Display screen 2 Power switch 4 Charging port 5 Cuff and wrapper 3 General connector ...

Страница 13: ...ort pressing to start cancel NIBP measurement 3 general connector It can be used to connect SpO2 probe 4 external DC power input socket Micro USB interface 5 Cuff it is used for wrapping patient s upper arm for NIBP measurement It is self bound to the device and can not be disassembled 6 Symbols and description ...

Страница 14: ...s SN Serial number Attention please refer to the User Manual Class II device Battery is fully charged rolling bar Battery is charging Following WEEE regulations for disposal Manufacturing date Wireless icon No alarms Do not litter at will Note the above signs and symbols may appear on your device ...

Страница 15: ...e sure the APP software connects to the Spot Check Monitor via wireless successfully For example of the host device with Android system and iOS system the APP software is installed in the following procedure 1 On the App Store of the device enter Vihealth into the search function Note if you use an iPad to search please select iPhone only when searching Instruction for Measurement Make sure the AP...

Страница 16: ...device displays software version number and UID and 1 5 seconds later it enters into the default screen as shown in figure 4 1 Figure 4 1 Default screen NIBP measurement screen Note If there is no signal or no operation for 3 minutes then the device will power off automatically Safety instruction before making measurement ...

Страница 17: ... and wrap it around the upper arm evenly to appropriate tightness The correct cuff position refers to figure 4 2 Note locate the cuff in such a way that direction mark directs to the lower arm Figure 4 2 Cuff placement 2 Adjust the testee s position Right position the testee should stand sit or lay down with calm condition and make the cuff and the testee s heart on the same level to get accurate ...

Страница 18: ...ment 4 When the measurement is finished the measured result and the corresponding emoji will be displayed on the screen refer to the following figure Figure 4 3 Screen Description battery capacity wireless icon Icon flashing means the host device is connecting to the device Icon staying ...

Страница 19: ...pressure PR 79 bpm it displays the measured value and the unit of pulse rate Emoji description it means the measured result is normal that is to say the measured SYS 130 and DIA 85 it means the measured result is high normal that is to say the measured SYS is between 130 and 159 and DIA is between 85 and 99 it means the measured result is abnormal that is to say the measured SYS is 160 and DIA 100...

Страница 20: ...k move the device shake body or arm For the same testee the testee should wait for 3 minutes for another NIBP measurement 4 2 SpO2 Measurement Optional Figure 4 4 SpO2 measurement screen Screen description SpO2 99 mark and value of oxygen saturation PR 62 mark and value of pulse rate ...

Страница 21: ... be not too long into the clip of the probe 3 Wait for 2 seconds the device will auto begin to make measurement 4 The measured result will be displayed on the screen as shown in figure 4 4 If the host device is connected to the device then the measured result can be displayed on the screen of the host device by running APP software 5 Remove the finger the prompt Finger out pops on the screen Note ...

Страница 22: ...ing range Systolic pressure 60mmHg 240mmHg Diastolic pressure 30mmHg 180mmHg 2 Blood pressure measuring accuracy mean difference 5mmHg standard deviation 8mmHg 3 Pneumatic system error 3mmHg 4 Pressure display resolution 1mmHg 5 2 SpO2 Measurement Optional 1 SpO2 measuring range 35 100 2 SpO2 measuring accuracy Arms is not greater than 2 for SpO2 range from 70 to 100 Note Arms is defined as root m...

Страница 23: ...easurement Optional 1 Pulse Rate measuring range 30bpm 240bpm 2 Pulse rate measuring accuracy 2bpm or 2 of reading whichever is greater 3 Resolution 1bpm Note when the measured PR 120bpm or PR 50bpm then the over limit PR value blinks 5 4 Wireless Communication 1 Emit and receiving frequency 2402MHz 2480MHz 2 The Channel number 40 3 Bandwidth 2 MHz 4 Modulation method GFSK ...

Страница 24: ...equipment 2 The degree of protection against electric shock Type B applied parts 3 The degree of protection against harmful ingress of liquid The equipment is IPX1 with protection against ingress of liquid 4 Electric magnetic compatibility Group I Class B 5 Mode of operation Continuous 5 6 Dimension and Weight Dimension 140 5mm L 60 0mm W 24 5mm H Gross Weight 260g ...

Страница 25: ...ortant information and maintenance measures 6 1 Technical Maintenance 6 1 1 Daily Examination Before using the device the following checks should be carried out Check the device for any mechanical damage Inspect the exposed parts and the connected parts for all the cables and the accessories Examine all the functions of the device that are likely to be used for measuring and ensure that it is in g...

Страница 26: ...tery from damage In order to maintain battery power and prolong battery lifetime please charge the battery routinely Generally charge the battery every 3 months if the device has not been used for more than 3 months 6 2 Cleaning and Disinfection of the Main Unit Switch off the device and disconnect the power adapter before cleaning Do NOT let any cleanser and disinfectant flow into the connector o...

Страница 27: ...the accessories clean and keep it in the packaging for maintenance after using 6 4 Storage If the device will not be used for long period of time wipe it clean and keep it in the package which shall be kept in a dry good ventilation place free from dust and corrosive gases Storage environment Ambient temperature 20 C 60 C Relative humidity 93 Atmospheric pressure 53 0kPa 106 0kPa ...

Страница 28: ...rts and try again No blood pressure result The cuff is wrapped around the arm incorrectly Wrap the cuff around the arm correctly No SpO2 result SpO2 probe is not inserted to the sensor connector or the finger is out of probe Plug SpO2 probe to the sensor connector and check if the finger is inserted into the probe properly Can not connect to the host device 1 Bluetooth version is not compatible 2 ...

Страница 29: ...inflate pressure to 30mmHg within 7 seconds The cuff is not well wrapped ERR 02 Cuff pressure is over 295mmHg Overpressure protection ERR 03 No valid pulse is detected ERR 04 Excessive motion artifact ERR 05 The measurement fails ERR 06 Air leakage Note the above error codes appears when the NIBP measurement fails ...

Страница 30: ...nual for Spot Check Monitor 22 CHAPTER 9 PACKING LIST Item Description Quantity Check 1 Spot Check Monitor One piece OK 2 User Manual One piece OK 3 SpO2 probe One piece Optional 4 Charging cable One piece OK ...

Страница 31: ...ty and the Invoice when you are requesting free repair 3 Please send the device to the specified place for repair 4 We will not offer free repair if one of the following condition exists Disassemble or refit the device arbitrarily Incorrect operation Drop immerse and collision of the device Incorrect repair by unauthorized personnel 5 The cost of repair beyond warranty will be taken by the charge ...

Страница 32: ...low form is applicable to adult with age over 18 years Blood Pressure Level SYS mmHg DIA mmHg Optimal blood pressure 120 80 Normal blood pressure 130 85 High normal blood pressure 130 139 85 89 Hypertension Grade 1 140 159 90 99 Hypertension Grade 2 160 179 100 109 Hypertension Grade 3 180 110 ...

Страница 33: ...User Manual for Spot Check Monitor 25 ...

Страница 34: ...k Monitor on March 26th 2014 Patent Number ZL 2013 2 0615696 X Shenzhen Creative Industry Co Ltd Floor 5 BLD 9 Baiwangxin High Tech Industrial Park Songbai Road Xili Street Nanshan District 518110 Shenzhen P R China Shanghai International Holding Corp GmbH Europe Eiffestrasse 80 20537 Hamburg Germany ...

Отзывы: