background image

Page 4

Page 1

CSV-REM Creamsource Remote User Manual – 07 Jan 2022

Version 1.0

3. Operation Cont.

4. Compliance

5. Contact Us

3.7 Individual Mode – Control Units Independently

This mode allows individual control of multiple Creamsource fixtures with one remote.
The DMX address must be set to either 1 or 2 in each Creamsource to use this feature.
Multiple Creamsource fixtures may share the same DMX address if you want them to
be controlled together. Creamsource fixtures should be daisy chained together using
DMX cable.

Hold the MODE button to switch between NORMAL and INDIVIDUAL modes. When in
INDIVIDUAL mode, Mode LED 1 or 2 will begin to flash. Tap the MODE button to switch
between controlling the fixture on DMX address 1 or 2. Independent levels and colour
settings can be set using the wheel and adjusted as needed. Note it is not possible to
have CCT on one fixture and HSI on another fixture.

To return to NORMAL mode, hold the MODE button again until the Mode LED stops
flashing.

5.1 Support

Have any questions? Feel free to get in touch

https://creamsource.com/support

4.1 Compliance Notes

This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (

1

) This device may not cause harmful interference, and (

2

)

This device must accept any interference received, including interference that may
cause undesired operation.

3.8 Locking The Buttons And Control Wheel

Hold the Power button down for two seconds to lock the buttons and control wheel.
The Mode 1 LED will ‘ping’ to show that the unit is locked, and the ring display will
pulse. Hold the Power Button again to unlock.

1.1 Overview

The Creamsource remote allows you to control one or more Creamsource fixtures with
a single controller. The 20 sunlight readable LEDs give accurate level indication, and
dedicated buttons allow the fixture to be turned on and off or flashed. If used with a
colour fixture the Green/Magenta and Hue/Saturation can also be adjusted.

The remote is plugged directly into the Creamsource Accessory port on either the
Micro, SpaceX, or Vortex fixtures. Note previous version of the remote (CS-REM) had a
different connector for direct connection to Doppio and Mini series fixtures.

To control more than one Creamsource, they can be daisy-chained together with DMX
cable between the DMX-IN and DMX-THRU ports.

1.2 Part Numbers

The table below lists part numbers for the Creamsource Remote.

Part Number

Description

CSV-REM

Creamsource Remote for Micro/SpaceX/Vortex Series

1. About the Creamsource Remote

Creamsource Remote

Quick Start Guide

Creamsource

2/49 Carrington Road Marrickville, NSW 2204 AUSTRALIA