AC Repair and Adjustment Procedures
FRP 3: Power Supply Replacement
HMM-168-A
Cray Research/Silicon Graphics Proprietary
21
FRP 3: Power Supply Replacement
It is not necessary to remove power from the cabinet when you perform this
procedure. (However, it is a good safety practice to do so.)
At all times during this procedure, ensure that you do not damage or touch the
gold-plated blades of the power supply’s output connector.
NOTE:
Refer to FN 2440 for information on isolating and tracking Phase 4
and Phase 5 power supply problems.
Part Number
•
13264100 (power supply, 3.3 Vac with thermal pad)
Tools Required
•
Small flatblade screwdriver
•
2.0-mm, 2.5-mm, and 3.0-mm hex sockets with torque driver
The sockets are included in “Socket set, Hex Bit 1/4” Drive Metric,” P/N
53267200, which is part of the T3E Tool Kit, P/N 15210200.
•
#1 Phillips screwdriver
•
Low-lint cloths/wipes
WARNING
Live voltage is present in the cabinet
during this procedure. Failure to avoid
live power components could result in
severe shock and burns.