Page 20 -
2.3.1
How do I do to see the error log for leveller?
H.
Connect the Service tool to connector X2 on Leveller board.
I.
Press LEFT BUTTON SW1, menu [L] is showed. Enter Leveller submenu by RIGHT BUTTON
SW2 L01 is showed
J.
Enter the submenu by RIGHT BUTTON SW2. The display now shows the latest error in the log (for
example “F11”). If there are no errors the display shows “End”.
K.
Press the LEFT BUTTON (SW1) to see next error codes. If there are no more error codes, the display
will show “End”.
L.
To leave the menu, press SW2.
M.
Press LEFT BUTTON (SW1) several times until the display shows [L], press three more time on
SW1 to exit from service menu.
Alternatively press LEFT BUTTON SW1 continuously for 2sec. to exit from service menu.
N.
The display now goes back to normal operation showing the state of the leveller, shelter or the door.
Alternatively the display showing active error codes.
2.4
Indication of time for service
If the set Service interval is reached, either in operating time or in number of cycles, the Service
indicator lamp on the control box will be lit. The lamp will remain lit until the service counters
are reset according to §2.2.3 and §2.2.4. By setting the service interval limit to 0 the indication
of time to service is disabled.
2.5
Limitations of the service tool display
The display has some important limitations that it might be good to know about.
The display consists of only three digits. When there are more than three numbers to show, the
display will scroll from right to left.
An example:
Let’s say that the total is 123456 cycles, it first shows 123, then 234, then 345 and finally 456.