Please Read This Before Installing Or Operating Pump. This
information is provided for 

SAFETY and to PREVENT EQUIPMENT

PROBLEMS.

 To help recognize this information, observe the

following symbols:

IMPORTANT!

 Warns about hazards that can result in

personal injury or Indicates factors concerned with
assembly, installation, operation, or maintenance which

could result in damage to the machine or equipment if ignored.

CAUTION !

   Warns about hazards that 

can or will cause minor

personal injury or property damage if ignored. Used with symbols
below.

WARNING ! 

  Warns about hazards that 

can or will cause serious

personal injury, death, or major property damage if ignored. Used
with symbols below.

 

Only qualified personnel should install, operate and repair pump. Any
wiring of pumps should be performed by a qualified electrician.

   WARNING !

 To reduce risk of electrical shock, pumps and

  control panels must be properly grounded in accordance
  with the National Electric Code (NEC) or the Canadian
  Electrical Code (CEC) and all applicable state, province,
  local codes and ordinances. Improper grounding voids
  warranty

  

WARNING !

 To reduce risk of electrical shock, always

  disconnect the pump from the power source before
  handling or servicing. Lock out power and tag.

 

WARNI NG !

 O per ation aga inst  a closed

discharge valve will cause premature bearing
and seal failure on any pump, and on end suction

and self priming pump the heat build may cause the generation of
steam with resulting dangerous pressures. It is recommended that
a high case temperature switch or pressure relief valve be installed
on the pump body.

  

CAUTION !

  Never operate a pump with a plug-in 

  type power cord without a ground fault 
  circuit interrupter.

  

CAUTION ! 

Pumps build up heat and pressure

  during operation-allow time for pumps to cool
  before handling or servicing.

  

WARNING !

  Do not pump hazardous materials

  (flammable, caustic, etc.) unless the pump is
  specifically designed and designated to handle them.

  

CAUTION !

 Do not block or restrict discharge hose,

  as discharge hose may whip under pressure.

  

WARNING !

 Do not wear loose clothing that may 

  become entangled in moving parts.

 

  WARNING ! 

Keep clear of suction and discharge

  openings. DO NOT insert fingers in pump with
  power connected.

 

 

  Always wear eye protection when working on pumps.

  Make sure lifting handles are securely fastened each 
  time before lifting. 

DO NOT

 operate pump without safety

  devices in place. Always replace safety devices that 
  have been removed during service or repair. Secure the
  pump in its operating position so it can not tip over, fall 
  or slide.

  DO NOT

 exceed manufacturers recommendation for

  maximum performance, as this could cause the motor 
  to overheat.

  

DO NOT

 remove cord and strain relief. 

DO NOT 

connect

  conduit to pump.

  

WARNING !

 Cable should be protected at all times to 

  avoid punctures, cut, bruises and abrasions. Inspect
  frequently. Never handle connected power cords with 
  wet hands.

  

WARNING !

  To reduce risk of electrical shock, all 

  wiring and junction connections should be made per 
  the NEC or CEC and applicable state or province and 
  local codes. Requirements may vary depending on 
  usage and location.

  

WARNING !

  Submersible Pumps are not approved for 

  use in swimming pools, recreational water installations
  decorative fountains or any installation where human
  contact with the pumped fluid is common.

  

 WARNING !

  Products returned must be cleaned,

   sanitized, or decontaminated as necessary prior to
   shipment, to insure that employees will not be exposed to
   health hazards in handling said material. All Applicable
   Laws And Regulations Shall Apply.

   Bronze/brass and bronze/brass fitted pumps may contain
   lead levels higher than considered safe for potable water
   systems. Various government agencies have determined
   that leaded copper alloys should not be used in 
   potable water applications. For non-leaded copper 
   alloy materials of construction, please contact factory.

  Crane Pumps & Systems, Inc. is not responsible for losses,
 injury, or death resulting from a failure to observe these
 safety precautions, misuse or abuse of pumps or equipment.

SAFETY  FIRST!

Hazardous fluids can
cause fire or explosions,
burns or death could result.

Extremely hot - Severe
burns can occur on
contact.

Eye protection
required

Hazardous voltage can
shock, burn or cause
death.

Toxic Fumes -
Breathing can cause 
nausea, fainting or death.

Hazardous pressure
Eruptions or explosions
could cause personal 
injury or property damage

Biohazard can cause 
serious personal injury.

Rotating machinery 
 Amputation or severe 
 laceration can result.

3

Содержание PROSSER PUPP512 Series

Страница 1: ...s Inc constant product improvement program product changes may occur As such Crane Pumps Systems Inc reserves the right to change product without prior written notification 420 Third Street P O Box 603 83 West Drive Brampton Piqua Ohio 45356 0603 Ontario Canada L6T 2J6 Phone 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com PUMPS SYSTEMS A Crane Co Company DISCON...

Страница 2: ...TER OPERATION 6 F PREVENTATIVE MAINTENANCE 6 TROUBLE SHOOTING 7 G REPLACEMENT PARTS 8 EXPLODED VIEW Fig 1 9 PUMP PARTS LIST 10 RETURNED GOODS POLICY 11 WARRANTY START UP REPORT WARRANTY REGISTRATION Other brand and product names are trademarks or registered trademarks of their respective holders Barnes is a registered trademark of Crane Pumps Systems Inc 1995 1997 1998 2002 2003 Alteration Rights ...

Страница 3: ...ge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT...

Страница 4: ... Silicon Carbide Motor End Rotating Face Carbon Stationary Face Ceramic Elastomer Buna N Hardware 300 Series Stainless CORD ENTRY 20 ft Cord w Plug Molded in Strain Relief And Compression Seal SPEED 3450RPM Nominal MOTOR Design NEMA Design N Single Phase Completely Oil Filled Insulation Class A SINGLE PHASE Permanent Split Capacitor PSC Includes Overload Protection In Motor STRAINER 25 6 4mm Openi...

Страница 5: ...rs For the location of the nearest Barnes Center check your Barnes Engineered catalog your Barnes representative or Barnes Service Department in Piqua Ohio telephone 937 778 8947 or Crane Pumps Systems Canada in Brampton Ontario 905 457 6223 SECTION C INSTALLATION C 1 Location Water feeding and discharging for construction and civil works Water supply and sewage works Various kinds of industrial f...

Страница 6: ...a Prosser Service Center WARNING DO NOT operate pump in reverse rotation as damage may result D 3 Start Up Start pumps one at a time to avoid excessive current draw on power supply DO NOT attempt to start a frozen pump Instead submerge pump in warm water for twenty 20 minutes before starting DO NOT attempt to thaw a frozen pump with a torch D 3 1 Report Included at the end of this manual are two s...

Страница 7: ... Clean impeller cavity and inlet of any obstruction 9 Loosenunion slightly toallow trapped air to escape Verify that turn off level of switch is set so that impeller cavity is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures as required to eliminate leakage 12 Check pump...

Страница 8: ...ion This number is used for ordering and obtaining information G 3 MODEL NUMBER This designation consist of numbers and letters which represents the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and obtaining information G 4 SERIAL NUMBER The Serial Number block will consist of a six digit number which is specific to each pump and m...

Страница 9: ...Fig 1 9 ...

Страница 10: ... Packing 9 1 Frame Packing 16 1 Suction Packing 33 1 Mechanical Seal 34 1 Oil Seal 35 1 Oil Seal 37 1 Screw 38 1 Seal Ring 39 1 Socket Bolt 40 1 Seal Washer 66 1 Supporter IMPELLER KIT PART No 096991 17 1 Impeller 18 0 2 Impeller Adjusting Washer 46 1 Toothed Washer 57 1 Nut 60 1 Screw Cover 68 1 Sleeve STRAINER KIT PART No 096992 7 1 Strainer 13 3 Stud Bolt 58 5 Nut 69 1 Base Plate HANDLE KIT PAR...

Страница 11: ...of the warranty contact your local Crane Pumps Systems Inc Distributor RETURNED GOODS RETURN OF MERCHANDISE REQUIRES A RETURNED GOODS AUTHORIZATION CONTACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable ...

Страница 12: ...r field performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall control Components or accessories su...

Страница 13: ...bottom Does Impeller Turn Freely By Hand YES NO Condition Of Equipment GOOD FAIR POOR Condition Of Cable Jacket GOOD FAIR POOR Resistance of Cable Jacket GOOD FAIR POOR Resistance of Cable and Pump Motor measured at pump control Red Black Ohms Red White Ohms White Black Ohms Resistance Of Ground Circuit Between Control Panel and Outside of Pump Ohms MEG Ohms Check of Insulation Red to Ground White...

Страница 14: ...n Pump Off L1 L2 L2 L3 L3 L1 Voltage supply at panel line connection Pump On L1 L2 L2 L3 L3 L1 Amperage Load connection Pump On L1 L2 L3 FINAL CHECK Is pump seated on discharge properly Check for leaks Does check valves operate properly Flow Does station appear to operate at proper rate Pump down time Noise Level High Medium Low Comments Equipment Difficulties during start up MANUALS Has operator ...

Страница 15: ...ERIAL NO PART NO BRAND FOLD HERE IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty Complete the Warranty Registration Form and returned to Crane Pumps Systems Inc Warranty Service Group IMPORTANT If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor ...

Страница 16: ...CRANE PUMPS SYSTEMS INC WARRANTY SERVICE GROUP 420 THIRD STREET P O BOX 603 PIQUA OHIO 45356 0603 U S A PLACE STAMP HERE FOLD HERE AND TAPE DO NOT STAPLE ...

Отзывы: