background image

SECTION A: GENERAL INFORMATION

A-1)  To the Purchaser:

Congratulations!

 You are the owner of one of the finest

pumps on the market today. Burks® Pumps are products
engineered and manufactured of high quality components.
Over eighty years of pump building experience along with a
continuing quality assurance program combine to produce a
pump which will stand up to the toughest pumping projects.
This manual will provide helpful information concerning
installation, maintenance, and proper service guidelines.

A-2) Receiving:

Upon receiving the pump, it should be inspected for damage
or shortages. If damage has occurred, file a claim
immediately with the company that delivered the pump. If the
manual is removed from the crating, do not lose or misplace.

A-3) Storage: 

Short Term - 

Burks Pumps are manufactured for efficient

performance following long inoperative periods in storage.
For best results, pumps can be retained in storage, as factory
assembled, in a dry atmosphere with constant temperatures
for up to six (6) months.

Long Term -

 Any length of time exceeding six (6) months,

but not more than twenty four (24) months. The units should
be stored in a temperature controlled area, a roofed over
walled enclosure that provides protection from the elements
(rain, snow, wind blown dust, etc.), and whose temperature
can be maintained b40 deg. F and +120 deg. F.
If extended high humidity is expected to be a problem, all
exposed parts should be inspected before storage and all
surfaces that have the paint scratched, damaged, or worn
should be recoated with a water base, air dry enamel paint.
All surfaces should then be sprayed with a rust-inhibiting oil.

A-4) Service Centers:

 

For the location of the nearest Burks Pumps Service Center,
check your catalog, your Burks Pumps representative or
Burks Pumps in Piqua, Ohio, telephone (937) 778-8947.

SECTION B: INSTALLATION RECOMMENDATIONS:

B-1) Location:

Locate the pump as close to the source of supply as possible.
Although the pump will operate on suction lifts of 25 feet, it
is desirable to keep the suction lift less than 15 feet, if
possible. The closer the pump can be located to the source
of supply, the faster the pump will prime and a greater
capacity can be pumped.

All pump units rotate clockwise when looking from the motor
end (driven end) of the pump. Also, rotation arrows are
located on the pump. On three phase units with threaded
suction/discharge connections the impellers are threaded on
the shaft and it is necessary to slide one half of the flexible
coupling back when checking rotation in order to eliminate
the possibility of unscrewing the impeller and damaging the
pump. 

NOTE:

 Where impellers thread on pump shaft, never

check the direction of electric motor rotation without first
disconnecting flexible coupling.

Locate the pump on a firm footing to make sure the pump will
not move due to vibration. Flex coupled and V-belt driven
units should be permanently grouted onto a cement
foundation. The pumps should be level to provide favorable
operating conditions. In addition, the flexible coupling should
be realigned after grouting in order to eliminate excessive
wear on the coupling.

 Allow a minimum of 18 inches in front of the pump case cover
or hatch cover to permit easy removal and access to the
interior of the pump. On belt driven units, allow a minimum
of 10 inches at the shaft end to permit easy removal of the
pedastal or rotating cartridge.

B-2) Suction:

It is advisable to use a suction line of the same size as the
pump port size. All horizontal suction lines should slope up
to the pump to avoid trapped air pockets. An adjustable
stand, pipe clamp or floor flange must be installed to support
the weight of the suction line. On suction lifts less than 5 feet,
it is sometimes possible to increase capacity slightly by
oversizing the suction line, but oversized suction pipe on high
suction lifts will create priming problems. Using a smaller
suction line than the pump port size can cause internal
damage to the pump.

The suction line must not have holes, even small holes. The
smallest air leak in the suction line may prevent the pump
from priming. Coat all threaded connections in the suction
line with pipe thread compound to insure an air tight joint. In
addition, suction flanges should be pulled up tight to prevent
air leaks. Where fiber gaskets are used, coat them with
grease.

5

Содержание burks pumps WB12

Страница 1: ...ua Ohio 45356 0603 Phone 937 778 8947 Fax 937 773 7157 www burkspumps com IMPORTANT Read all instructions in this manual before operating pump As a result of Burks Pumps constant product improvement program product changes may occur As such Burks Pumps reserves the right to change product without prior written notification PUMPS SYSTEMS A Crane Co Company DISCONTINUED Parts may NOT be available Ma...

Страница 2: ...IONS 6 D MAINTENANCE RECOMMENDATIONS 6 8 TROUBLE SHOOTING 9 E REPLACEMENT PARTS 10 RETURNED GOODS POLICY 12 Other brand and product names are trademarks or registered trademarks of their respective holders Burks Pumps is a registered trademark of Crane Pumps Systems Inc Burks Pumps Inc 1997 2001 2003 Alteration Rights Reserved Printed in U S A 2 ...

Страница 3: ...tion and discharge openings DO NOT insert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall...

Страница 4: ...t to laboratory tests corrected for field performance Any additional guarantees in the nature of performance specifications must be in writing and such writing must be signed by our authorized representative Due to inaccuracies in field testing if a conflict arises between the results of field testing conducted by or for user and laboratory tests corrected for field performance the latter shall co...

Страница 5: ...e closer the pump can be located to the source of supply the faster the pump will prime and a greater capacity can be pumped All pump units rotate clockwise when looking from the motor end driven end of the pump Also rotation arrows are located on the pump On three phase units with threaded suction discharge connections the impellers are threaded on the shaft and it is necessary to slide one half ...

Страница 6: ...of all the water 4 The discharge of a self priming centrifugal pump may be closed briefly without damaging the pump However the water will soon heat up and this can damage the pump seal 5 It is not desirable to run the pump without liquid in the pump case If the pump must be run in order to check the operation of the engine or motor fill the case with sufficient water to keep the rotating seal wet...

Страница 7: ...sembly 1 and 2 or 1A and 2A see Figure 2 in pump side adapter 12 using SAE 10 oil on the rubber parts They may install easier by first inserting the rubber part and then sliding the seat part into the rubber All of this must be done with the fingers only Now assemble the spring and rotating portion of the seal onto the impeller shaft 19 Lubricate the impeller shaft 19 and the inside of the bellows...

Страница 8: ...FIGURE 3 8 ...

Страница 9: ...logged foot valve strainer or pump 6 Defective wearplate s 1 Repair or replace suction line 2 Refill reprime pump casing before restarting 3 Lower suction head install foot valve and primer 4 Increase inlet pressure by adding more water to tank or increasing back pressure by turning gate valve on discharge line to partially closed position 5 Unclog clear or replace as necessary 6 Replace Pump over...

Страница 10: ...1 Pump serial number and date code 2 Pump model number 3 Pump part number 4 Part description 5 Item part number 6 Quantity required 7 Shipping instructions 8 Billing Instructions IMPORTANT When Ordering Parts ALWAYS Provide The Complete Part Number Serial Number and Model Number INFORMATION SUBJECT TO CHANGE WITHOUT NOTICE 1 2 3 10 ...

Страница 11: ... Crane Pumps Systems Inc 1994 2001 NOTES 11 ...

Страница 12: ...TACT YOUR LOCAL CRANE PUMPS SYSTEMS INC DISTRIBUTOR Products Returned Must Be Cleaned Sanitized Or Decontaminated As Necessary Prior To Shipment To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply ...

Отзывы: