It is advisable that all three phase control panels be 
purchased from the factory.

SECTION: C START-UP OPERATION

C-1) Check Voltage and Phase:

Before operating pump, compare the voltage and phase 
information stamped on the pump’s identifi cation plate to the 
available power.

C-2) Check Pump Rotation:

Before putting pump into service for the fi rst time, the motor 
rotation must be checked. Improper motor rotation can result 
in poor pump performance and can damage the motor and/
or pump. To check the rotation, suspend the pump freely, 
momentarily apply power and observe the “kickback”. 
“Kickback” should always be in a counter-clockwise direction 
as viewed from the top of the pump motor housing and will 
always be in the opposite direction of the rotation arrows 
cast in the pump volute.

C-2.1) Incorrect Rotation for Three-Phase Pumps:

In the event that the rotation is incorrect for a three-phase 
installation, interchange any two power cable leads at 
the control box. Recheck the “kickback” rotation again by 
momentarily applying power.

C-2.2) Test Procedure For Moisture Sensor Control:

With a moisture detection control, a normally closed push 
button and neon indicating lamp is typically provided as a 
means of checking the moisture sensing components. When 
the push button is depressed, the indicating lamp will be 
illuminated to indicate (A) power is supplied to the control, 
(B) the control is operative, and (C) wiring to the moisture 
sensing probes in the motor is intact. This procedure should 
be performed periodically to confi rm integrity of the circuit.

C-3) Start-Up Report:

Included at the end of this manual is one start-up report 
sheet, this sheet is to be completed as applicable. Return 
a copy to Barnes and store the second in the control panel 
or with the pump manual. It is important to record this data 
at initial start-up since it will be useful to refer to should 
servicing the pump be required in the future.

C-3.1) Identifi cation Plate:

Record the numbers from the pump’s identifi cation plate on 
the START-UP REPORT provided at the end of the manual 
for future reference.

FIGURE 5

Содержание 6SHMJ150N6

Страница 1: ... 937 778 8947 Phone 905 457 6223 Fax 937 773 7157 Fax 905 457 2650 www cranepumps com Form No 125508 Rev AJ This product may be covered by one or more of the following patents and other patent s pending US Patent 7 931 473 8 128 360 21 Frame 3SHV Vortex Pumps 15 30HP 3450RPM 4SHV Vortex Pumps 15 30HP 3450RPM 15HP 1750RPM 4SHM Monovane Pumps 7 5 30HP 1750RPM 7 5 20HP 1150RPM 4SHD Dual Vane Pumps 7 ...

Страница 2: ...ENDED MINIMUM SUCTION CLEARANCE Fig 9 23 SH CROSS SECTIONS Fig 9 10 EXPLODED VIEWS Fig 11 24 25 PARTS LISTS 26 43 WARRANTY 45 RETURNED GOODS POLICY 46 WARRANTY REGISTRATION 46 START UP REPORT 47 48 Other brand and product names are trademarks or registered trademarks of their respective holders Barnes is a registered trademark of Crane Pumps Systems Inc 1995 1997 1998 1 2004 4 05 1 06 3 06 9 06 12...

Страница 3: ...sert fingers in pump with power connected Always wear eye protection when working on pumps Make sure lifting handles are securely fastened each time before lifting DO NOT operate pump without safety devices in place Always replace safety devices that have been removed during service or repair Secure the pump in its operating position so it can not tip over fall or slide DO NOT exceed manufacturers ...

Страница 4: ...47 or Crane Pumps Systems Canada in Brampton Ontario 905 457 6223 SECTION B INSTALLATION B 1 Location These self contained pumping units are recommended for use in a sump lift station or basin This pump is designed for submerged continuous duty 15 minutes duty in air at nameplate horsepower pumping sewage effluent wastewater or other nonexplosive or noncorrosive liquids not above 104 F 40 C Never in...

Страница 5: ...ws into the clamping plate Slowly tighten the two screws alternating back and forth until the clamping plate is drawn down flush to the top of the cord boss on the pump The two screws should be torqued until the plate is down to a point where metal to metal contact is made between the stainless steel plate and pump housing See Fig 2 The cord assembly mounted to the pump must not be modified in any w...

Страница 6: ...208 3 60 3450 E 54 1 1 2 59 0 195 7 88 5 125498 8 4 18 4 1 12 02 247 988 230 48 9 1 2 57 1 125498 8 4 18 4 1 12 02 460 24 4 1 2 28 5 125497 12 4 18 4 87 02 4SHVA15052 15 0 575 3 60 3450 E 19 5 1 2 22 8 70 8 125497 12 4 18 4 87 02 1 61 4SHVA20082 20 0 230 3 60 3450 J 50 8 1 2 59 0 189 0 125498 8 4 18 4 1 12 02 089 356 460 25 4 1 2 29 7 125497 12 4 18 4 87 02 4SHVA20052 20 0 575 3 60 3450 J 20 3 1 2...

Страница 7: ...8 8 4 18 4 1 12 02 187 748 230 46 9 1 2 54 3 206 6 125498 8 4 18 4 1 12 02 460 23 4 1 2 27 2 103 3 125497 12 4 18 4 87 02 4SHVB15054 15 0 575 3 60 1750 E 18 7 1 2 21 7 82 6 125497 12 4 18 4 87 02 1 16 4SHVBA 4SHVBA25042 25 0 460 3 60 3450 G 30 8 1 2 36 7 189 0 125499 8 4 18 4 1 12 02 356 4SHVBA25052 25 0 575 3 60 3450 G 24 6 1 2 29 4 151 2 125497 12 4 18 4 86 02 545 4SHVBA30042 30 0 460 3 60 3450 ...

Страница 8: ...5497 12 4 18 4 87 02 510 4SHMD30044 30 0 460 3 60 1750 F 38 9 1 2 45 9 191 9 125499 8 4 18 4 1 12 02 337 4SHMD30054 30 0 575 3 60 1750 F 31 1 1 2 36 7 153 5 125499 8 4 18 4 1 12 02 510 4SHMD75N6 7 5 208 3 60 1150 J 24 9 1 2 29 6 137 6 125496 12 4 18 4 87 02 329 230 24 0 1 2 27 6 460 12 0 1 2 13 8 68 8 125497 87 02 1 315 4SHMD7556 7 5 575 3 60 1150 J 9 6 1 2 11 0 55 0 125497 12 4 18 4 87 02 1 960 4...

Страница 9: ...8 4 18 4 1 12 02 151 230 44 1 1 2 51 4 460 22 0 1 2 25 7 124 3 125497 12 4 18 4 87 02 603 4SHME15056 15 0 575 3 60 1150 H 17 6 1 2 20 6 99 4 125497 12 4 18 4 87 02 934 4SHME20046 20 0 460 3 60 1150 E 28 6 1 2 34 9 124 3 125499 8 4 18 4 1 12 02 603 4SHME20056 20 0 575 3 60 1150 E 22 9 1 2 27 9 99 4 125497 12 4 18 4 87 02 934 4SHMEA Pump 4SHMEA100N6 10 0 208 3 60 1150 F 32 9 1 2 41 0 137 6 125498 8 ...

Страница 10: ...91 9 125499 8 4 18 4 1 12 02 337 4SHDI25054 25 0 575 3 60 1750 G 26 6 1 2 31 1 153 5 125497 12 4 18 4 87 02 510 4SHDI30044 30 0 460 3 60 1750 F 38 9 1 2 45 9 191 9 125499 8 4 18 4 1 12 02 337 4SHDI30054 30 0 575 3 60 1750 F 31 1 1 2 36 7 153 5 125499 8 4 18 4 1 12 02 510 4SHDI75N6 7 5 208 3 60 1150 J 24 9 1 2 29 6 137 6 125496 12 4 18 4 87 02 329 230 24 0 1 2 27 6 460 12 0 1 2 13 8 68 8 125497 87 ...

Страница 11: ... 4 87 02 329 230 24 0 1 2 27 6 460 12 0 1 2 13 8 68 8 125497 12 4 18 4 87 02 1 315 6SHVL7556 7 5 575 3 60 1150 J 9 6 1 2 11 0 55 0 125497 12 4 18 4 87 02 1 960 6SHVL100N6 10 0 208 3 60 1150 F 32 9 1 2 41 0 137 6 125498 8 4 18 4 1 12 02 329 230 30 2 1 2 35 8 460 15 1 1 2 17 9 68 8 125497 12 4 18 4 87 02 1 315 6SHVL10056 10 0 575 3 60 1150 F 12 1 1 2 14 3 55 0 125497 12 4 18 4 87 02 1 960 6SHVL150N6...

Страница 12: ...4 30 0 575 3 60 1750 F 31 1 1 2 36 7 153 5 125499 8 4 18 4 1 12 02 510 6SHMH100N6 10 0 208 3 60 1150 F 32 9 1 2 41 0 137 6 125498 8 4 18 4 1 12 02 329 230 30 2 1 2 35 8 460 15 1 1 2 17 9 68 8 125497 12 4 18 4 87 02 1 315 6SHMH10056 10 0 575 3 60 1150 F 12 1 1 2 14 3 55 0 125497 12 4 18 4 87 02 1 960 6SHMH150N6 15 0 208 3 60 1150 H 47 0 1 2 56 8 248 6 125498 8 4 18 4 1 12 02 151 230 44 1 1 2 51 4 4...

Страница 13: ...5054 25 0 575 3 60 1750 G 26 6 1 2 31 1 153 5 125497 12 4 18 4 87 02 510 6SHDO75N6 7 5 208 3 60 1150 J 24 9 1 2 29 6 137 6 125496 12 4 18 4 87 02 329 230 24 0 1 2 27 6 460 12 0 1 2 13 8 68 8 125497 12 4 18 4 87 02 1 315 6SHDO7556 7 5 575 3 60 1150 J 9 6 1 2 11 55 125497 12 4 18 4 1 12 02 1 960 6SHDO100N6 10 0 208 3 60 1150 F 32 9 1 2 41 137 6 125498 8 4 18 4 87 02 329 230 30 2 1 2 35 8 460 15 1 1 ...

Страница 14: ...2 41 0 137 6 125498 8 4 18 4 1 12 02 329 230 30 2 1 2 35 8 460 15 1 1 2 17 9 68 8 125497 12 4 18 4 87 02 1 315 6SHDK10056 10 0 575 3 60 1150 F 12 1 1 2 14 3 55 0 125497 12 4 18 4 87 02 1 960 6SHDK150N6 15 0 208 3 60 1150 H 47 0 1 2 56 8 248 6 125498 8 4 18 4 1 12 02 151 230 44 1 1 2 51 4 460 22 0 1 2 25 7 124 3 125497 12 4 18 4 87 02 603 6SHDK15056 15 0 575 3 60 1150 H 17 6 1 2 20 6 99 4 125497 12...

Страница 15: ... 9 1 2 41 137 6 125498 8 4 18 4 1 12 02 329 230 30 2 1 2 35 8 460 15 1 1 2 17 9 68 8 125497 12 4 18 4 87 02 1 315 8SHDU10056 10 0 575 3 60 1150 F 12 1 1 2 14 3 55 125497 12 4 18 4 87 02 1 960 8SHDU150N6 15 0 208 3 60 1150 H 47 0 1 2 56 8 248 6 125498 8 4 18 4 1 12 02 151 230 44 1 1 2 51 4 460 22 0 1 2 25 7 124 3 125497 12 4 18 4 87 02 603 8SHDU15056 15 0 575 3 60 1150 H 17 6 1 2 20 6 99 4 125497 1...

Страница 16: ...otor Lead ID Green Ground Green Black 1 Red 2 White 3 Jumpered Inside Cord Automatically No user jumpering required T4 T5 T6 Together T11 T7 Together T13 T9 Together T12 T8 Together MOISTURE AND TEMPERATURE SENSORS MOISTURE AND TEMPERATURE SENSORS Control Cable Control Cable Lead ID Lead ID Green Ground Green Brown P1 Temperature Sensor Yellow P2 Temperature Sensor Orange W1 Moisture Sensor Blue W...

Страница 17: ...isture Sensors A normally open N O detector is installed in the pump seal chamber which will detect any moisture present and a continuity test resistor built into the motor The test resistor is rated 1 watt at 330K ohms The moisture sensors MUST be connected to moisture detector control in the control panel which includes a continuity test circuit see Figure 4 for typical wiring diagram The normal...

Страница 18: ...ads at the control box Recheck the kickback rotation again by momentarily applying power C 2 2 Test Procedure For Moisture Sensor Control With a moisture detection control a normally closed push button and neon indicating lamp is typically provided as a means of checking the moisture sensing components When the push button is depressed the indicating lamp will be illuminated to indicate A power is...

Страница 19: ...ump on it s side and drain oil into a clean dry container 2 Check oil for contamination using an oil tester with a range to 30Kilovolts breakdown 3 If oil is found to be clean and uncontaminated measure above 15 KV breakdown refill the seal chamber as per section E 1 2 4 If oil is found to be dirty or contaminated or measures below 15 KV breakdown the pump must be carefully inspected for leaks at t...

Страница 20: ...n either seal face DO NOT interchange seal components replace the entire shaft seal 4 If replacing seal remove stationary 4A from mounting plate by prying out with flat screw driver E 3 2 Reassembly Lightly oil DO NOT use grease outer surface of stationary member 4A Press stationary member 4A firmly into mounting plate using a seal pusher aligning seal with pin nothing but the seal pusher is to come...

Страница 21: ... F 3 MODEL NUMBER This designation consists of numbers and letters which represent the discharge size series horsepower motor phase and voltage speed and pump design This number is used for ordering and obtaining information F 4 SERIAL NUMBER The serial number block will consist of a six digit number which is specific to each pump and may be preceded by an alpha character which indicates the plant ...

Страница 22: ...k impeller for freedom of operation security and condition Clean impeller and inlet of any obstruction 9 Loosen union slightly to allow trapped air to escape Verify that turn off level of switch is set so that the suction is always flooded Clean vent hole 10 Check rotation If power supply is three phase reverse any two of three power supply leads to ensure proper impeller rotation 11 Repair fixtures ...

Страница 23: ...C 3XSHVC 3 00 76 2 3SHVR 3XSHVR 3SHVRA 3XSHVRA 3 50 88 9 3SHMPA 3XSHMPA 4SHMS 4XSHMS 3 75 95 3 4SHDF 4XSHDF 4SHVA 4XSHVA 4 00 101 6 4SHVB 4XSHVB 4SHVBA 4XSHVBA 4 25 108 4SHMC 4XSHMC 4SHDG 4XSHDG 4SHMD 4XSHMD 4 75 120 7 6SHVL 6XSHVL 5 25 133 4 6SHDO 6XSHDO 5 50 139 7 4SHMB 4XSHMB 6 00 152 4 4SHME 4XSHME 4SHMEA 4XSHMEA 4SHDI 4XSHDI 6SHMN 6XSHMN 6 50 165 1 6SHMH 6XSHMH 6SHMJ 6XSHMJ 6SHDK 6XSHDK 6SHVT...

Страница 24: ...24 FIGURE 10 SH Pump Series Cross Sections FIGURE 11 SH Vortex SH Enclosed ...

Страница 25: ...25 FIGURE 12 SH Pump Series Exploded Views ...

Страница 26: ...Impeller 50 x 1 50 18 8 SS 9 See Table O Ring 9A 2 125857 245 O Ring M3 x 245 70 Duro Buna N 9B 1 125857 220 O Ring M3 x 220 70 Duro Buna N 10 See Table Wear Ring Volute Bronze 10A See Table ƒ Wear Ring Impeller 11 See Table Volute Cast Iron 12 029034 Seal Chamber Oil Fill Oil 13 7 125850 Screw SKT FCHS M10 x 1 5 x 20 14 2 014270 SS Plug Pipe 0 375 18NPT SS 16 1 125457 Retainer Bearing 3309 Ductil...

Страница 27: ...in 28 4mm 125499XJ 75 400 600 59 0 8 4 18 4 1 12in 28 4mm 125499XL 100 400 600 59 0 8 4 18 4 1 12in 28 4mm 37 1 127249 Wire Jumper Green 6 Bar O Ring 8G 38 2 039462 Tie Cable 39 1 125855 Screw SHCS M5 x 0 8 x 8 Stainless Steel 41 1 127270 Plug Cap 3 37 Tapered PE 42 2 125856 Sensor Moisture 18NPT AMP PP SS 43 1 125450A Bracket Bearing 21 Frame Class 30 CI 44 1 130685 Housing Motor 21 Frame Upper C...

Страница 28: ...600 130689P 138589 129998 125857 360 4SHMEA 370mm 137226 139234 130689P 138589 129998 125857 360 4SHDF 208mm Not Available in 21 Frame 4SHDG 240mm 129994 138602 130687P 138587 129997 125857 235 4SHDI 370mm 127254 138600 130689P 138589 129998 125857 360 6SHVL 370mm 130831 138606 130689P 138589 N A 125857 360 6SHVT 465mm Not Available in 21 Frame 6SHMN 370mm 130830 138603 130689P 138589 130833 12585...

Страница 29: ...54B 143272B 200mm 7 87in 125454BTA 143272BTA 195mm 7 68in 125454BTB 143272BTB 205mm 8 07in 125454 143272 200mm 7 87in 125454TA 143272TA 195mm 7 68in 125454TB 143272TB 190mm 7 48in 125454TC 143272TC 185mm 7 28in 125454TD 143272TD 180mm 7 09in 125454TE 143272TE 175mm 6 89in 125454TF 143272TF 170mm 6 69in 125454TG 143272TG 165mm 6 50in 125454TH 143272TH 160mm 6 30in 125454TJ 143272TJ 155mm 6 10in 125...

Страница 30: ...0826TL 143279TL 310mm 12 20in 130826TM 143279TM E Impeller Trim Dia mm in Ductile Iron Part No Nihard Part No 370mm 14 57in 127261 143274 365mm 14 37in 127261TA 143274TA 360mm 14 17in 127261TB 143274TB 355mm 13 98in 127261TC 143274TC 350mm 13 78in 127261TD 143274TD 345mm 13 58in 127261TE 143274TE 340mm 13 45in 127261TF 143274TF 335mm 13 19in 127261TG 143274TG 330mm 12 99in 127261TH 143274TH 325mm ...

Страница 31: ...828TH 143283TH 285mm 11 22in 130828TJ 143283TJ 280mm 11 02in 130828TK 143283TK 275mm 10 83in 130828TL 143283TL 270mm 10 63in 130828TM 143283TM 265mm 10 43in 130828TN 143283TN 260mm 10 24in 130828TP 143283TP 255mm 10 04in 130828TQ 143283TQ 250mm 9 84in 130828TR 143283TR 245mm 9 65in 130828TS 143283TS 240mm 9 45in 130828TT 143283TT 235mm 9 25in 130828TU 143283TU 230mm 9 06in 130828TV 143283TV 225mm ...

Страница 32: ... 5 71in 137353TU 143920TU EA Impeller Trim Dia mm in Ductile Iron Part No Nihard Part No 370mm 14 57in 137225 143289 365mm 14 37in 137225TA 143289TA 360mm 14 17in 137225TB 143289TB 355mm 13 98in 137225TC 143289TC 350mm 13 78in 137225TD 143289TD 345mm 13 58in 137225TE 143289TE 340mm 13 39in 137225TF 143289TF 335mm 13 19in 137225TG 143289TG 330mm 13 00in 137225TH 143289TH 325mm 12 80in 137225TJ 1432...

Страница 33: ...KIT 143293TB 290mm 11 42in 138102TC KIT 143293TC 285mm 11 22in 138102TD KIT 143293TD 280mm 11 02in 138102TE KIT 143293TE 275mm 10 82in 138102TF KIT 143293TF 270mm 10 63in 138102TG KIT 143293TG 265mm 10 43in 138102TH KIT 143293TH 260mm 10 24in 138102TJ KIT 143293TJ 255mm 10 04in 138102TK KIT 143293TK 250mm 9 84in 138102TL KIT 143293TL 245mm 9 64in 138102TM KIT 143293TM 240mm 9 45in 138102TN KIT 143...

Страница 34: ...ector Clip 24 Orange Wire Jumper Impeller Attachment Kit includes Impeller Washer Impeller Bolt Seal Kit includes Volute O Ring option 1 Volute O Ring option 2 Volute O Ring option 3 Volute O Ring option 4 Seal Plate Upper O ring Stator Upper and Lower O rings Terminal Block O ring External Retaining Ring Key Upper Mechanical Seal Lower Mechanical Seal NOTE Kit contains hardware your pump may not ...

Страница 35: ...Kit Purchase Seal Kit and Hardware Kit Leg Kits Model Leg Kit Part No Leg Kit Height Inches mm 3SHVC 125506 3 15 80 3SHVR 125506 3 15 80 3SHVRA 125506 3 15 80 3SHMPA 125506 3 15 80 4SHMS 125506 3 15 80 4SHDF 125506 3 15 80 4SHVA 125506 3 15 80 4SHVB 125506 3 15 80 4SHVBA 125506 3 15 80 4SHMC 125506 3 15 80 4SHDG 125506 3 15 80 4SHMD 125506B 6 50 165 6SHVL 125506 3 15 80 6SHDO 125506B 6 50 165 4SHM...

Страница 36: ... SH 20084 138723 138732 SH 20054 131993 132069 SH 25044 138724 138737 SH 25054 131995 132071 SH 30044 131996 138736 SH 30054 131997 132073 SH 150Z4 138672 138673 SH 220Z4 138674 138675 SH 185Z4 138676 138677 SH 110Z4 138678 138679 SH 55Z4 138680 138681 Example Model No Rotor Kit Part No Stator Motor Housing Kit Part No 4SHVB25052 131975 132051 1150 RPM Model No Rotor Kit Part No Stator Motor Housi...

Страница 37: ...77 138597 138586 138611 138594 138616 138613 138614 139236 125506 N A 4SHVB20052 131973 132049 138577 138597 138586 138611 138594 138616 138613 138614 139236 125506 N A 4SHVB20082 131972 132048 138577 138597 138586 138611 138594 138616 138613 138614 139236 125506 N A 4SHVB25042 131974 132050 138577 138597 138586 138611 138594 138616 138613 138614 139236 125506 N A 4SHVB25052 131975 132051 138577 1...

Страница 38: ...7556 132916 138720 138577 138599 138588 138611 138594 138616 138613 138614 139236 125506B N A 4SHMD75N6 132915 132933 138577 138599 138588 138611 138594 138616 138613 138614 139236 125506B N A 4SHMD10056 132918 132936 138577 138599 138588 138611 138594 138616 138613 138614 139236 125506B N A 4SHMD100N6 132917 132935 138577 138599 138588 138611 138594 138616 138613 138614 139236 125506B N A 4SHMD15...

Страница 39: ... 139236 125506 N A 4SHDG20084 138723 138732 138577 138602 138587 138611 138594 138616 138613 138614 139236 125506 N A 4SHDG7556 132916 138720 138577 138602 138587 138611 138594 138616 138613 138614 139236 125506 N A 4SHDG75N6 132915 132933 138577 138602 138587 138611 138594 138616 138613 138614 139236 125506 N A 4SHDI150N4 131990 132066 138581 138623 138624 138625 138633 138634 138577 138600 13858...

Страница 40: ...HVL30044 131996 138736 138577 138606 138589 138611 138594 138616 138613 138614 139236 125506 N A 6SHVL30054 131997 132073 138577 138606 138589 138611 138594 138616 138613 138614 139236 125506 N A 6SHVL7556 132916 138720 138577 138606 138589 138611 138594 138616 138613 138614 139236 125506 N A 6SHVL75N6 132915 132933 138577 138606 138589 138611 138594 138616 138613 138614 139236 125506 N A 6SHVL100...

Страница 41: ... A 6SHMN75N6 132915 132933 138577 138603 138589 138611 138594 138616 138613 138614 139236 125506B N A 6SHMH30044 131996 138736 138581 138623 138624 138625 138633 138634 138577 138603 138589 138611 138594 138616 138613 138614 139236 125506B N A 6SHMH30054 131997 132073 138577 138603 138589 138611 138594 138616 138613 138614 139236 125506B N A 6SHMH10056 132918 132936 138577 138603 138589 138611 138...

Страница 42: ...38577 140146 138588 138611 138594 138616 138613 138614 139236 125506B N A 6SHDK25044 138724 138737 138581 138623 138624 138625 138633 138634 138577 138604 138589 138611 138594 138616 138613 138614 139236 125506B N A 6SHDK25054 131995 132071 138577 138604 138589 138611 138594 138616 138613 138614 139236 125506B N A 6SHDK30044 131996 138736 138577 138604 138589 138611 138594 138616 138613 138614 139...

Страница 43: ...6 125506B 8SHDU75N6 132915 132933 138577 140148 138588 138611 138594 138616 138613 138614 139236 125506B 8SHDU7556 132916 138720 138577 140148 138588 138611 138594 138616 138613 138614 139236 125506B 8SHDU100N6 132917 132935 138577 140148 138588 138611 138594 138616 138613 138614 139236 125506B 8SHDU10056 132918 132936 138577 140148 138588 138611 138594 138616 138613 138614 139236 125506B 8SHDU150...

Страница 44: ...Notes ...

Страница 45: ... support any Warranty claims This Warranty shall not apply to any product or part of product which has been subject to misuses negligence accident operation outside of our published hydraulic curve parameters used in a manner contrary to printed Instructions or damaged due to a defective power supply improper electrical protection excessive abrasive wear or faulty installation or repair THE SOLE A...

Страница 46: ... Hazards In Handling Said Material All Applicable Laws And Regulations Shall Apply IMPORTANT WARRANTY REGISTRATION Your product is covered by the enclosed Warranty To complete the Warranty Registration Form go to http www cranepumps com ProductRegistration If you have a claim under the provision of the warranty contact your local Crane Pumps Systems Inc Distributor IMPORTANT WARRANTY INFORMATION W...

Страница 47: ...O___ Type _________________________________ Number and size of short circuit device s ___________ Amp rating ___________________ Overload Type _____________ Size ______________ Amp rating ___________________ Do protection devices comply with pump and motor Amp rating YES___ NO___ Are all electrical and panel entry connections tight YES___ NO___ Is the interior of the panel dry YES___ NO___ Liquid ...

Страница 48: ... OHYHO FRQWUROV LQVWDOOHG DZD IURP WXUEXOHQFH 6BBB 12BBB V OHYHO FRQWURO RSHUDWLQJ SURSHUO 6BBB 12BBB V SXPS IXOO VXEPHUJHG GXULQJ RSHUDWLRQ 6BBB 12BBB ROORZ XS RUUHFWLYH FWLRQ 5HTXLUHG 6BBB 12BBB GGLWLRQDO RPPHQWV BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB BBBBBBBBBBBBBBBBBBBBBBBBBBBBBBB...

Отзывы: