Error Message
Fault Description
Additional information
Mug Sensor SureVend Error
Mug sensor blocked
since bootup
If there is nothing present in the cup
station. Then, either the mug sensors are
misaligned or sensors are faulty. The
machine will be taken out of service if this
error occurs. This error will be cleared once
the above mentioned issues are fixed.
Dispense Head Not Homed
Dispense head home
operation failed.
Machine will be taken out of service, as the
machine can no longer dispense a drink.
This error is normally a result of faulty
home switch.
Dispense Head Not
Extended
Dispense head extend
operation failed.
Machine will be taken out of service as it
can no longer dispense any more drinks.
This error is normally a result of faulty opto
sensor.
Dispense Head Motor Not
Enabled
Dispense head unable to
move at all
If the software is unable to detect any
activity on opto sensor then it will raise this
error. The error can be down to faulty
motor or faulty opto sensor.
Brewer Jam
Unable to detect switch
input in the given time
out for Uni
-
Paper or
Oltre paperless brewer
present in the machine.
This will disable all drinks based on this
particular brewer.
Brewer Waste Pail Full
Brewer waste capacity is
exceeded
This error will only be raised if brewer
waste management is enabled. It will
disable all fresh brew drinks. The drinks will
only be enabled after the counters are
reset from the service menus.
Brewer Jam (CoEx®)
Error while operating the
CoEx® brewer
Motor is stalled or is taking more current
than the allowed limit.
Water filter replacement
required
Overall water filter usage
has exceeded the set
limit. Water filter needs
to be changed.
This error is only raised if water filter
counters are enabled. Once the error is
raised no further drinks could be taken
until the counter is reset from service
menus.
Water Tank Leak
Main Boiler is
experiencing water
leakage.
This error is raised if the main boiler
requests fill operation 15 times even
though none of the valves attached to it
were operated.
Low Water
Main boiler is running
low on water.
This error will be cleared once main boiler
is filled up.
Содержание COTI
Страница 1: ...Part Number PR15937000 Issue A 09 2017 Technical Manual ...
Страница 9: ...Technical Manual IX Table of Contents ...
Страница 35: ...Technical Manual 26 Section 4 Customising the User Interface ...
Страница 106: ...97 COTI ICON Section 7 Technical Information ...
Страница 109: ...Technical Manual 100 Section 8 Espresso System 8 2 1 Water Flow Diagram ...
Страница 110: ...101 COTI ICON Section 8 Espresso System ...
Страница 112: ...103 COTI ICON Section 9 Dispense Pipe Lengths ...
Страница 128: ...119 COTI ICON Section 11 Electrical Electronic Diagrams 11 2 Touch Screen ICON ...
Страница 131: ...Technical Manual 122 Section 11 Electrical Electronic Diagrams ...
Страница 133: ...Technical Manual 124 Section 11 Electrical Electronic Diagrams 11 6 Input Circuit 1 ...
Страница 134: ...125 COTI ICON Section 11 Electrical Electronic Diagrams 11 7 Input Circuit 2 ...
Страница 135: ...Technical Manual 126 Section 11 Electrical Electronic Diagrams 11 8 Output Circuit 1 ...
Страница 136: ...127 COTI ICON Section 11 Electrical Electronic Diagrams 11 9 Output Circuit 2 ...
Страница 137: ...Technical Manual 128 Section 11 Electrical Electronic Diagrams 11 10 Power Circuit Instant and Freshbrew Machines ...
Страница 138: ...129 COTI ICON Section 11 Electrical Electronic Diagrams 11 11 Power Circuit Espresso Machines ...