- 44 -
SETTINGS OF THE INSTALLATION TYPES
3.2 - Access the lines 501 to 755
After setting the parameters via the QAA 73
room sensor, and so that the LMU accepts
the modifications to the settings, press the
RESET button on the boiler control panel,
wait for 6 seconds and press a second time.
-
!
Buttons
Explanation
Line
1
et
Press on the both line selection buttons
and setting buttons
beginning with the button
- This will take you to the first programming mode "LMU"(4. level)
Successive display:
2
Press both line selection buttons for at least 3 seconds.
- This will take you to the second programming mode "LMU" (5. level)
Successive display:
3
Press the line selection buttons to select the required line.(rep. b).
. . .
4
Press the plus or minus button to enter the required value (rep. c). The setting will be stored as soon as
you leave the programming mode (by pressing the Info button) or change to another line.
P R OG
TH
I-
53
-3
TH
I-
54
-0
P R OG
c)
b)
TH
I-
55
-3
TH
I-
56
-0
P R OG