- 30 -
INSTALLATION
3.2.4.4 - Polypropylene/PVC concentric
bends (option)
Joint fitting.
Each 45° bend added reduces the total permitted
length by 0.5m.
Each 90° bend added reduces the total permitted
length by 1m.
3.2.4.5 - Polypropylene roof plate (option)
3.2.4.6 - Fastening collar (option)
These collars are essential to fix the vertically posi-
tioned extensions so that the boiler outlet does not
bear the weight of the conduits.
3.2.4.7 - Adapting collar for the vertical balan-
ced flue
See assembly instructions for the part.
Reference
Type of bend
Æ
int.
mm
Æ
ext.
mm
N40.28395
45°
80
125
N40.28396
90°
80
125
Reference
Colour
A90.12172
noir
Reference
Quantity
Æ
mm
B00.29727
3
125
AM5-
24-
0
90° bend
Fig. 29
45° bend
AM5-27-0
Fig. 30
AM5-26-0
Fig. 31
Reference
V00.24253
THI
100-
0
Fig. 32
Содержание THI 10-50c
Страница 61: ... 64 XII NOMENCLATURE THRi 10 50 C ...
Страница 64: ... 67 NOMENCLATURE CONTROL BOX ...
Страница 66: ... 69 NOTES ...