Super Shot 125 Diesel Melter Part Manual
Chapter 8 Troubleshooting (43600, 43800 and 45500)
©2017 by Crafco, Inc. All Rights Reserved………………...……………Troubleshooting (43600, 43800, and 45500) 8-26
Symptom: Trigger is not Working
8.3.3
Step
Possible Cause
If . . .
1
Check continuity between two red wires
coming from the hose in junction box.
NOTE:
These wires must be disconnected
from the terminal block and the trigger
depressed to perform this test.
•
Yes, go to
•
No, go to Step 2.
2
Disconnect the electrical connector between
the hose and wand, check for continuity
between C and B wand side.
•
Yes, this hose needs to be repaired or
replaced. Contact Crafco, Inc. to send
back the hose for repair.
•
No, this wand needs to be repaired or
replaced. Contact Crafco, Inc. to send
back the hose for repair.
Table 8-22 Trigger is Not Working