Chapter 8 Troubleshooting (43600, 43800 and 45500)
©2017 by Crafco, Inc. All Rights Reserved………………...……………Troubleshooting (43600, 43800, and 45500) 8-5
Step
Possible Cause
If . . .
12a
Is there 12Vdc between bottom terminal of
circuit breaker (red wire) and nearby ground
source (black wire)?
•
Yes, replace circuit breaker.
•
No, go to Step 13.
13
Is there 12Vdc between “ACC” (red wire) of
ignition switch and nearby ground source
(black wire)?
•
Yes, check for loose or broken wires
between “ACC” of ignition switch and
bottom terminal of circuit breaker.
•
No, go to Step 13a.
13a
Is there 12Vdc between “B” (blue wire) of
ignition switch and nearby ground source
(black wire)?
•
Yes, replace ignition switch.
•
No, go to Step 14.
14
Is there 12Vdc between blue wire on starter
solenoid and nearby ground source (black
wire or bare metal on engine case)?
•
Yes, check for loose or broken wire
between starter solenoid and ignition
switch.
•
No, go to step 14a.
14a
Check connections and condition of red
battery cable.
•
Yes, there should be 12Vdc at all previous
steps.
•
No, replace battery cable.
Table 8-6 Burner Electrical Troubleshooting (continued)
Содержание SUPER SHOT 125
Страница 1: ...Parts Manual 26631 Revision D SUPER SHOT 125 DIESEL MELTER ALL MODELS...
Страница 4: ...Super Shot 125 Diesel Melter PN 43600 Super Shot 125 Diesel Melter with Compressor 100 CFM PN 47400...
Страница 20: ......
Страница 24: ......
Страница 28: ......
Страница 64: ......
Страница 68: ......
Страница 224: ......
Страница 228: ......
Страница 229: ......
Страница 230: ...2017 Crafco Inc...