Super Shot 60 Diesel Melter Part Manual
Chapter 8 Troubleshooting
©2016 by Crafco, Inc. All Rights Reserved
………………...………………………………..……………...Troubleshooting 8-8
8.0.4. Testing the DC Controller
Step
Bench Test DC Controller
1
Remove all wire nuts attaching the DC Controller to the burner.
2
Attach the black ground wire to the negative battery post.
3
Attach the red wire to the positive battery post.
4
Attach the white (Enable) wire to the positive battery post to start the test. (Genesis II
Controllers will have a 15-second delay.)
Orange (Blower Motor) wire should have 12Vdc (all the time).
Blue (Igniter) wire should have 12Vdc.
• Purple (Fuel Solenoid) wire should have 12Vdc (after the delay).
5
Twist the yellow wires together (once voltage registers) on the orange, blue and purple wires.
Orange (Blower Motor) wire should maintain 12Vdc.
Blue (Igniter) wire should lose voltage after 15 seconds.
Purple (Valve) wire should maintain 12Vdc.
• Purple (Fuel Solenoid) wire should maintain 12Vdc.
6
If any of the above tests fail, replace the DC Controller.
8.0.5. Burner Fuel Solenoid Testing
Step
Fuel Solenoid Test
1
Remove cord set from fuel solenoid.
2
Check the ohms between the terminals of fuel solenoid.
3
If the reading is between 15-25 ohms the coil is good.
4
If the reading is outside the above range or the meter indicates an open circuit, replace the
fuel solenoid.
Table 8-9 Testing the DC Controller
Table 8-10 Burner Fuel Solenoid Testing
Содержание SS60-Diesel
Страница 1: ...Parts Manual 26618 Revision B ...
Страница 4: ...SUPER SHOT 60 DIESEL SKID MOUNT MELTER PN 46800 SUPER SHOT 60 DIESEL TRAILER MELTER PN 46950 ...
Страница 5: ......
Страница 8: ...Super Shot 60 Diesel Melter Part Manual Table of Contents 10 0 Tools and Accessories 10 1 ...
Страница 14: ......
Страница 18: ......
Страница 24: ......
Страница 44: ......
Страница 48: ......
Страница 114: ......
Страница 118: ......
Страница 119: ... 2016 Crafco Inc ...