EZ 500 Series II Melter Part Manual
Chapter 8 Troubleshooting
©2019 by Crafco, Inc. All Rights Reserved………………...………………………………..……………...Troubleshooting 8-29
8.4 Pump Troubleshooting
Symptom: Material Does Not Dispense When the Pump is Activated
8.4.1
Step
Possible Cause
If . . .
1
Is the Hose Temperature Display at or above
325°F?
•
Yes, go to Step 2.
•
No, continue to allow the hose to heat.
(Make sure the Hose dial is set at proper
operating temperature.)
2
Is the red "Pump" light "ON"?
•
Yes, go to Step 3.
•
3
Is the hose selector switch in the
“ELECTRIC” position as well as the pump
switch should be in “ON ELECTRIC”
position?
•
Yes, go to Step 4.
•
No, move the toggle switches to the proper
positions.
4
With the wand in the shoebox, pull the wand
trigger and look at the material pump shaft
coupler.
Is it spinning clockwise?
•
Yes, shut down machine and look for a plug
in the plumbing.
•
No, adjust the material flow control to
increase the flow.
•
Still no, go to Step 5.
5
Inside the control box and under the front
panel, find the relay cube for the pump. It is
found near the middle, left-hand side of the
box. It is a clear yellow cube with a green
button facing the top of the control box. When
the trigger is engaged does the green light
illuminate?
•
Yes, this indicates that 12Vdc is reaching
Electrical Troubleshooting (continued)
5 to find the problem.
•
, Steps 2 to find the
problem.
6
Is the hydraulic fluid level near the center of
the sight gauge when the machine is cold?
See
Fig. 5.1 Hydraulic Fluid Level and Temp.
•
Yes, go to
•
No, fill oil to the center of the sight gauge.
Table 8-26 Basic Visual Pump Troubleshooting
Содержание EZ 500 Series II
Страница 1: ...Parts Manual 26603 Revision K...
Страница 4: ...EZ500 Series II Melter Electric Hose PN 46100EB EZ500 Series II Melter Standard Hose PN 46100SB...
Страница 12: ......
Страница 14: ......
Страница 22: ......
Страница 38: ......
Страница 52: ......
Страница 130: ......
Страница 134: ......
Страница 135: ......
Страница 136: ...2019 Crafco Inc...