EZ 500 Series II Melter Part Manual
Chapter 6 Maintenance Instructions
©2019 by Crafco, Inc. All Rights Reserved………………..…………………………………..….…Maintenance Instructions 6-3
6.11 Replacing Heat Transfer Oil
1. Drain oil by removing oil drain cap located under machine.
2. Open ball valve located rear driver’s side of machine before refilling. This allows the air to
escape the center column.
3. Start burner and heat the heat transfer oil until one drop of oil comes out of ball valve.
4. Close ball valve immediately.
(CAUTION: HOT OIL WILL CAUSE SEVERE BURNS)
NOTE: THIS PROCEDURE IS NOT REQUIRED FOR DAILY OPERATION
.
200
220
240
260
280
300
320
340
360
380
400
Calibration Mark
Knob
Fig. 6.2 Temperature Control Calibration