4.6
Gas connection
WARNING
4
Close the main gas valve before starting work on the
gas pipes.
4
Before mounting, check that the gas meter has
sufficient capacity. To do this, you should keep in
mind the consumption of all appliances.
4
If the gas meter has a too low capacity, inform the
energy supply company.
1. Remove the anti-dust plug located on the gas connection
GAS/
GAZ
under the boiler.
2. Connect the gas inlet pipe.
3. Mount a gas isolation valve on this pipe, directly under the boiler.
4. Connect the gas pipe to the gas shut off valve.
CAUTION
4
Ensure that there is no dust in the gas pipe.
4
We recommend installing a gas filter on the gas pipe
to prevent clogging of the gas valve unit.
4
Connect the gas pipe in accordance with prevailing
standards and regulations.
4.7
Connections for the air and exhaust pipes
The boiler is suitable for the following types of flue gas
connections.
¼
See chapter: "Certifications", page 8.
4.7.1.
Classification
The table specifies this classification in detail according to
[
.
Type
Execution
Description
B23
B23P
(1)
Open
4
Without fire-stop approval.
4
Exhaust of combustion gases above the roof.
4
Air in the installation room.
B33
Open
4
Without fire-stop approval.
4
Common exhaust of combustion gases above the roof.
4
Common exhaust of combustion gases mixed in the air, air in the installation room (special
construction).
C13
Closed
4
Vent in the outside wall.
4
The opening for the air-supply inlet is located in the same pressure zone as the vent (For
example, a common passage through the outside wall).
(1) Including the pressure classification P1
(2) EN483: 0,5 mbar suction by pressure reduction
(3) An under pressure of 4 mbar is possible
(4) See table for minimum sizes of duct or sleeving
T002859-C
4. Installation
Quinta Pro 30 - 45 - 65 - 90 - 115
22
250413 - 123157-03
Содержание Quinta Pro 115
Страница 7: ...250413 123157 03 5 ...
Страница 88: ...10 Checklists Quinta Pro 30 45 65 90 115 86 250413 123157 03 ...
Страница 89: ...Quinta Pro 30 45 65 90 115 10 Checklists 250413 123157 03 87 ...
Страница 90: ...10 Checklists Quinta Pro 30 45 65 90 115 88 250413 123157 03 ...
Страница 91: ......