Страница 1: ...OPERATION MANUAL Pro Set TRA21 SERIES Mobile Multiple Refrigerant Recovery Recycle System Certified by ITS to meet SAE J2810 for R 134a Designed to meet new SAE J2851 for R 1234yf ...

Страница 2: ...systems Convertible for Commercial recovery Small High Side volume eliminates pump down system Fast and easy convertible instructions All components mounted on a heavy duty roll cage Easy to carry handle integrated into the roll cage Models TRA21 TRA21C and TRA21S include tank overfill sensor cord High Pressure cutout switch This manual contains important information on the proper procedures for o...

Страница 3: ... heart arrhythmia loss of consciousness or even cause suffocation DANGER ELECTRICAL SHOCK HAZARD Always disconnect power source when servicing this equipment DANGER EXPLOSION RISK Do not recover flamable refrigerants CAUTION All hoses may contain liquid refrigerant under pressure Contact with refrigerant may cause frostbite or other related injuries Wear proper personal protective equipment such a...

Страница 4: ...ents Included TRA21 TRA21C TRA21S TRA21E R 134a Manifold Hose Set Included Included Included 30 lb DOT Recovery with Overfill Sensor Included Included Included Overfill Sensor Cord Included Included Included Suction Hose Included Discharge Hose Included Included Included Included Oil Drain Bottle and Hose Included Included Included Included R 1234yf Low Side Coupler Included R 134a Low Side Couple...

Страница 5: ...port 2 Oil drain valve and port 3 Base unit 4 High pressure indicator light 5 Overfill sensor cord and indicator light not included on the TRA21E 6 Roll cage handle 7 Discharge Port 8 Oil seperator 9 Drier with moisture indicator 6 5 5 4 3 7 9 8 2 1 ...

Страница 6: ... tank 3 Connect the Yellow Overfill Sensor Cord to the float in the recovery tank This cord is not inclueded on the model TRA21E For the TRA21E use scale to monitor tank weight All connections should be done as shown in Diagram 1 4 Open the vapor valve on the recovery tank 5 Start unit by pushing main power switch to the ON position 6 Open the HI and LO side manifold valves to start the refrigeran...

Страница 7: ...OPERATION Diagram 1 ...

Страница 8: ...at in the recovery tank This cord is not included on the model TRA21E For the TRA21E use scale to monitor tank weight All connections should be done as shown in Diagram 2 5 Open the vapor valve on the recovery tank 6 Start unit by pushing main power switch to the ON position 7 Open the HI and LO side manifold valves to start the refrigerant flow 8 Run for 15 minutes to allow liquid refrigerant to ...

Страница 9: ...Diagram 2 OPERATION ...

Страница 10: ...d into the system and placed in the storage tank Liquid filter drier manitenance The TRA21 is equipped with a 16 cubic inch filter drier with an integrated moisture indicator This filter should be checked and replaced periodically This filter drier removes any moisture that may be contained in the recovered refrigerant Replace the filter drier as follows Caution Always assume the presence of high ...

Страница 11: ...ts off Solution The high pressure switch has activated Make sure the discharge valve and recovery tank valve s are open Check for any other restrictions on the discharge port of the unit Correct restriction Restart the unit Problem TOS Red LED lights up and the unit shuts off or will not start Solution 1 Check to make sure TOS cord is properly plugged into the recovery tank float 2 Check tank weig...