CPS FlexOM-PP Скачать руководство пользователя страница 1

Quick Guide for 

FlexOM-PP-Meter

10/17/2021
Revision 2

Environment

Operating Temperature Range

Relative Humidity

Max. Operating Altitude

Dimensions (W * H * D)

Weight

Mechanical

Protection Degree

Installation Options

-40℃ ~ 60℃ (-40℉~ 140℉)

4% ~ 85%

4,000 m (13,123 ft.) 

350 * 550 * 190 mm

19 kg

IP65

Wall Mounting, Pole Mounting

NEMA4 enclosure

Breaker, 3P 600V

Include component

Transformer, 600/480/240/208V Primary, 110V Secondary

AC-DC Power supply, 85~264 VAC input, 12V output, 40W

Gateway built-in 4G module, optional data plan

Содержание FlexOM-PP

Страница 1: ...H D Weight Mechanical Protection Degree Installation Options 40 60 40 140 4 85 4 000 m 13 123 ft 350 550 190 mm 19 kg IP65 Wall Mounting Pole Mounting NEMA4 enclosure Breaker 3P 600V Include component Transformer 600 480 240 208V Primary 110V Secondary AC DC Power supply 85 264 VAC input 12V output 40W Gateway built in 4G module optional data plan ...

Страница 2: ... A B A B Cable Gland1 Gland2 Gland3 Gland4 Gland5 Gland6 Gland7 Inverter ID 1 Inverter ID 32 Weather Sensor Connect to 3rd party data logger Gateway can connect up to 32 devices through RS485 interface Don t use the Modbus ID 165 A5H 0XA5 It is reserved for broadcast commands of CPS inverters Transformer 600 480 240 208 0 110 0 Power Supply N L V V Breaker L1 L2 L3 LA LB LC ...

Страница 3: ... t e w a y w i t h e n c l o s u r e FlexOM PP Meter is equipped with a NEMA4 enclosure Gateway is its core component Mount the gateway to the DIN rail with clip Then fix the antenna in a suitable position outside the chassis ...

Страница 4: ...Page 3 FlexOM PP Meter pole mounting Long rod bolt M8 Nut M8 Front U rail Rear U rail Chassis hook Chassis hanging hole ...

Страница 5: ... mounting Drilling holes in the wall Front U rail Expansion screw sleeve Self tapping screw Wrench Use a wrench to adjust the hook screw to fasten the chassis to the bracket Chassis hook Chassis hook The back of the chassis hook ...

Страница 6: ...AN CONSUMPTION STATISTICS ARE NOT PROVIDED At the same time FlexOM gateway does not guarantee the 3rd party SIM card The user needs to manually enter the APN FlexOM hardware warranty is valid by default within the validity period of our data plan 1 Pull to open the slot 2 Open the cover of slot Place the chip of the SIM card facing down with the notch facing the corresponding position of the card ...

Страница 7: ...tems com Internet interface 4G FlexOM SIM card supports AT T T mobile at the same time After the gateway is powered on and works normally it will select and connect to the provider network with the strongest or most stable signal If you need to purchase FlexOM SIM please contact CPS US sales staff for detailed information Scan the QR code to complete APP download and installation by using the mobi...

Страница 8: ...ption A A B G Vin GND A B G Interfaces on FlexOM Main Board B Terminating Resistance Switch Default 1 ON Caution If the length of the cable connecting to RS485 port or AUX port of the gateway is over 1000 meters the Switch button must be set to ON Power Switch POWER ON Caution Before configuring the gateway pay attention to set the power switch to ON ...

Страница 9: ...nd MQTT CPS Server Primary MQTT FOMlink CPS Connect Pro APP Router When the inverters are monitored via the gateway a unique RS 485 address for each inverter can be set up through the LCD interface Up to 32 inverters can be connected in the daisy chain network and different FlexOM packages have different specific number restrictions ...

Страница 10: ... 2 Phillips bit 2 Replace the screws with the 3 standoffs included in the gateway kit Install the gateway by carefully align ing the 6 PIN connector in the upper left hand corner of the communication board Install the 3 screws into the stand offs to secure the gateway in place Install the 3 screws and torque to 7 in lbs using a 2 Phillips bit 6 PIN Connector 6 PIN Header 3 ...

Страница 11: ...g the 5 Pin Connector provided in the gateway kit NOTE The 5 Pin Connector is installed on the port on the bottom of the inverter communication board behind the gateway The RJ45 LAN cable is inserted into the Ethernet port of the gateway The LAN cable must be able to access the Internet without port filtering behind the firewall 5 A B G Vin GND A B G RS485 of 3rd Party Data Logger RS485 Inverter D...

Страница 12: ...again that the gateway s power switch is set to on Pass the cable through the disassembled cable gland parts in sequence then tighten the cable glands again Screw one end of the antenna cable into the cable connector of the gateway Screw the other end of the antenna cable into the antenna ...

Страница 13: ... enclosure includes a DIN rail mounting clip for installation in a NEMA4 communication box FlexOM Suite Open the gateway enclosure and Install the 4 screws into the standoffs to secure the gateway in place Installation Option External in a NEMA4 enclosure B 93 mm 90 mm 37 mm ...

Страница 14: ...RS485 Cable 3rd Party Data Logger SCADA The RS485 interface of the third party controller is connected to the AUX interface of the gateway which is equivalent to a direct transmission connection with a daisy chain Inverter or ESS RS485 Cable 3rd Party Portal ...

Страница 15: ...ss through CPS Portal Ethernet Cable 3rd Party Data Logger SCADA The gateway can be used as a modbus TCP server connect to a third party SCADA system and forward various commands to the daisy chain Inverter or ESS RS485 Cable 3rd Party Portal ...

Страница 16: ... allows users to connect different brands and models of hardware in the same daisy chain via RS485 The connected hardware needs to be pre compatible with FlexOM If the user s hardware is not yet compatible CPS US will complete the compatibility free of charge Inverter or ESS RS485 Cable Model A Model B Meter Weather Sensor EV Charger ...

Страница 17: ...ller SCADA 3rd Party Server 3rd Party Controller SCADA APP Inverter RSD CPS Portal 3rd Party Server Modbus TCP MQTT HTTP POST extra MQTT RS485 TTL RS232 485 option Open API option 8 5 The gateway sends raw data unidirectionally to a third party server via HTTPS extra MQTT 1 3 The APP connects to the gateway through BLE 4 2 for on site configuration and diagnosis 7 4 6 INV ESS CPS portal 3rd party ...

Страница 18: ...alla tion tab Ensure the D2XH cable and FOMlink are connected to the gateway The APP will list the BLE name of FOM link starting with CPLK and the SN of FOMlink is the BLE name CPS Connect Synchronizing data 20 V 1 0 6 Installation OM Service Flex Gateway Dongle Gateway No LCD Inverter Rename FOMlink Scan Devices APP Settings Connect to WiFi mode Refresh CPLK 000AA77 way nverter Rename FOMlink ...

Страница 19: ... 6 FG4C 408800000000022 2 2 2251 00 00 5E 11 13 C0 3 0035 Offline GMT 6 mqtt chintpowersystems 1884 DHCP enabled 9600 N8 1 Quit CPLK 000001211 Next Scan Daisy Chain Send Log Modbus ID Range Inverter Baud Rate Fullscreen More Internet Settings Show Status Important Click Show Status to display the current configuration parameters of the gateway The gateway connects to the Internet through 4G by def...

Страница 20: ...6565645 Disable Disable Quit CPLK 000001211 Next Scan Daisy Chain Send Log Modbus ID Range Inverter Baud Rate Fullscreen More Internet Settings Show Status Click 4G Cellular or Ethernet to enable this connection method When returning to the previous screen click OK to save the settings Click Show Status to check the connec tion status Before the status becomes Online click Next will only display G...

Страница 21: ...eway Gateway Name Country Site Name None None None Time Zone None Done Installation Success Enter the site name and gateway name and then select the country and time zone of site Click Next to change the settings on the portal ...

Страница 22: ...t CPLK 000001211 Next Scan Daisy Chain Send Log Modbus ID Range Inverter Baud Rate Fullscreen More Internet Settings Show Status If any errors occur on site click Send Log to request remote assistance Confirm your phone is set to access the Internet Upload Back Connected the Cloud Click the button to upload the log Click Upload to send the process of installation Call CPS service to troubleshoot t...

Страница 23: ...odify the scope of the gateway to scan daisy chain devices Internet Settings Change how the gate way connects to the Internet MQTT Server Enable the secondary MQTT server s parameters HTTPS Server Enable the HTTPS POST to a 3rd party s server Upgrade Firmware To upgrade the gate way to the latest Reboot Only restart the gateway it will not erase any settings Reset This will restore the gateway to ...

Страница 24: ...or Secondary MQTT Ethernet port Modbus TCP Internal installation RS485 DC Input 6 Pin External installation RS485 DC Input 5 Pole 3 5 mm pitch EDG Only one effective at the same time between port A and B RS485 3 Pole A B G RJ45 10Base T 100Base T 4Pin connector General data Voltage supply 4G Cellular module WiFi module LTE FDD LTE TDD WCDMA GSM EDGE Option 802 11 b g n Input voltage Power consumpt...

Отзывы: