E-Mail: [email protected] - Internet: www.cpn.de
3
Preliminary note
Please read manuals of the installed systems to make sure that all safety requirements are fulfilled at any
time.
Safety Instructions
An external fuse or circuit breaker (max. 20A) must be provided in the onsite installation as
an interrupt facility for the Enclosure system. – Only applicable for AC powered systems!
WARNING Risk of electrical shock, fire, personal injury or death.
Do not use a power supply without proper grounding (Protective Earth). Use the terminal on the
input block for earth connection. Make sure that protective earth is connected according to all
local and national codes and regulations!
Turn power off before working on the device. Protect against inadvertent re-powering.
Make sure that the wiring is correct by following all local and national codes.
Do not modify or repair the unit.
Do not open the electronic units, e.g. power supply, as high voltages are present inside.
Use caution to prevent any foreign objects from entering into the housing.
Do not use in wet locations or in areas where moisture or condensation can be expected while
cover is not mounted.
Do not touch during power-on, and immediately after power-off. Hot surface may cause burns.
Terminology and Abbreviations
PE
PE is the abbreviation for Protective Earth and has the same meaning as the symbol.
Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”.
T.B.D.
To be defined, value or description will follow later.
AC 230V
A figure displayed with the AC or DC before the value represents a nominal voltage with
standard tolerances (usually ±15%) included.
E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V)
230Vac
A figure with the unit (Vac) at the end is a momentary figure without any additional
tolerances included.
50Hz vs. 60Hz As long as not otherwise stated, AC 100V and AC 230V parameters are valid at 50Hz and
AC 120V parameters are valid at 60Hz mains frequency.
may
A key word indicating flexibility of choice with no implied preference.
shall
A key word indicating a mandatory requirement.
should
A key word indicating flexibility of choice with a strongly preferred implementation.
DCE
data communication equipment
DTE
data terminal equipment
Required Tools
Phillips screwdriver
PH3
enclosure lid
Phillips screwdriver
PH2
battery
Slotted screwdriver
0.6x3.5mm
terminal blocks
Wrench
#8
pole mount enclosure & IDP terminal
Wrench
#10
LoRaWAN antenna
Wrench
#13
solar panel
Zip ties
Wire cutter