
MPA Hub Mount I&O Manual
Meters screen
The meters screen can be accessed by pressing F3 while in any of the
parameter set screens similar to Figure B-9.
All five operating parameters are monitored on this screen:
Helix Voltage & Current, RF output & reflected power and the current
attenuator setting. They are shown in both a graphical (color bar graphs) and
numerical format.
RF output bar graph shows the current alarm (yellow area) and fault trip (red
area) settings. Reflected RF and Helix current show the trip setting in red.
Helix voltage shows the under and over voltage trip levels also in red.
The wide bar graph is the current “analog value” with the numeric or
“digital” value in the box above the bar graph.
Figure B-10 Meters screen
Doc. 01031254 Rev. 1
Setup & remote control software B-7
Содержание T04CO
Страница 32: ...I N S T A L L A T I O N 2 10 Installation and Operation Manual This page is intentionally left blank ...
Страница 41: ...M P A H U B M O U N T Figure 3 5 Remote Control Unit Menu Tree Doc 01031254 Rev 1 3 9 ...
Страница 68: ...O P E R A T I O N 5 10 Installation and Operation Manual This page intentionally left blank ...
Страница 74: ...D R A W I N G S 7 2 Installation and Operation Manual This page is intentionally left blank ...
Страница 92: ...MPA Hub Mount I O Manual C 2 Replaceable parts Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 94: ...MPA Hub Mount I O Manual D 2 Optional Linearizer Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 96: ...MPA Hub Mount I O Manual E 2 Optional L band BUC Doc 01031254 Rev 1 This page is intentionally left blank ...
Страница 112: ...MPA Hub Mount I O Manual Appendix G 14 Doc 01031254 Rev 1 This page is intentionally left blank ...