Figure 5-11. Setup (4/5)
Figure 5-12. Setup (5/5)
5.3.5.3 Calibration
The first page in CALIBRATION gives the operator the ability to offset and blank either the RF
output or reflected RF. The offset is used to match the output power with the front panel power
reading. Blanking inhibits noise power from being displayed on the front panel. To do this the
operator must set the blanking just above the noise level detected on the front panel.
The second page in CALIBRATION is the RF output sample calibration offsets. This page will
be displayed only if the optional RF output monitor port J4 is present on the Indoor SSPA.
The third page in CALIBRATION is the RF input sample calibration offsets. This page will be
displayed only if the optional RF input monitor port is present on the Indoor SSPA. Figure 5-13
to figure 5-15 shows the calibration screens