Gas-Fired Vented
  Room Heater

INSTALLATION AND

OPERATING INSTRUCTIONS

P/N 80900   -   REV. 12/03

This appliance is equipped with  a safety control system designed to protect against

improper venting of combustion products.

THIS UNIT IS NOT TO BE INSTALLED IN MOBILE HOMES.

  WARNING:  If the information in this manual is not
   followed  exactly, a fire or explosion may result
  causing property damage, personal injury or loss of
  life.

-

Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.

-

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone
in your building.

Immediately call your gas supplier from a neighbor’s
phone.  Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire
department.

-

INSTALLATION AND SERVICE MUST BE
PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.

WARNING:  Operation of this heater when not connected to a properly installed and maintained
venting system or tampering with the vent safety shut-off system can result in Carbon Monoxide
(CO) poisoning and possible death.

RADIANT FRONT

CLOSED FRONT

This unit is not approved for installation in mobile homes, greenhouses, or environments involving
dusty, wet, corrosive, or explosive conditions.  Such conditions will invalidate the warranty and may
create unsafe conditions.

The coating selected to provide longer life
to the heat exchanger may smoke slightly
upon initial firing.  Provide adequate venti-
lation if this occurs.

  

NATURAL GAS   VC201A    VC351A     VC501A    VC701A    VCR351A     VCR501A     VCR701A

 PROPANE GAS    VC202A    VC352A     VC502A    VC702A    VCR352A     VCR502A     VCR702A

R

R

Содержание VC201A and

Страница 1: ...instructions If you cannot reach your gas supplier call the fire department INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER SERVICE AGENCY OR THE GAS SUPPLIER WARNING Operation of this heater when not connected to a properly installed and maintained venting system or tampering with the vent safety shut off system can result in Carbon Monoxide CO poisoning and possible death RAD...

Страница 2: ...0 Batterymarch Street Boston Massachusetts 02110 Canadian standards are available from International Approval Services 178 Rexdale Boulevard Etobicoke Ontario Canada M9W 1R3 The design of this appliance was certified to comply with ANSI Z21 11 1 vented room heaters and CAN1 2 1 M86 Installer must leave these instructions with the consumer have them complete and return the warranty card ROOM HEATER...

Страница 3: ... switch when activated will extinguish the pilot flame If the homeowner experiences this problem the vent system must be checked and corrected NOTE An existing vent that has worked for years may not be adequate for todays design because of higher efficiency requirements resulting in lower stack temperatures The following is a list of possible causes and corrective actions POSSIBLE CAUSES CORRECTIV...

Страница 4: ...guyed or braced if it extends more than five 5 feet above roof See Termination diagram above Firestop Support Assembly Vertical Vent Elbow Listed Appl Terminate vent at least 5 ft above draft hood CONNECTING THE VENT INTO AN EXISTING CHIMNEY SAFE See Venting NOTE Thismayresult intheventsafetyswitch shuttingdownthepilot dependingonsizeand drawofchimney FIGURE7A 1 4 UNSAFE FIGURE7B RECOMMENDED Use p...

Страница 5: ...pply piping during any pressuretestingofthatsystematthetestpressureinexcess of psig Theappliancemustbeisolatedfromthegassupplypiping byclosingitsindividualmanualshutoffvalveduringany pressure testing of the gas supply piping system at test pressures equal to or less than psig LOCATION AND SPEICAL PRECAUTIONS Due to high temperatures the appliance should be located out of traffic and away from furn...

Страница 6: ...st spaces cannot be blocked with insulation or other objects Each of these openings using vertical ducts shall have a minimum free area of one square inch per 4 000 btu hr of total input rating of all gas appliances See Figure B and C If horizontal ducts are used the minimum free area shall be one square inch per 2 000 btu hr of total input rating of all gas appliances Fresh make up air can also b...

Страница 7: ...jections such as a mantle or window sill is 22 on the 20 35 and 19 inches on the 50 70 models with a maximum horizontal extension of 18 inches The clearances around the air opening into the combustion chamber must be maintained and the burner must be kept clean Do not permit dust or dirt to accumulate here The other clearances previously mentioned must be maintained There must be adequate room pro...

Страница 8: ...ezel by placing bezel tabs over lower front and swing bezel into position and secure with three screws MAIN BURNER ORIFICE This appliance was shipped from the factory with an orifice sized to give the correct gas input using the gas for which the heater was equipped There may be local conditions such as variation in gas pressure or BTU content of the gas which may be cause for a change in the orif...

Страница 9: ...lean out hole 8 Clean the rear chamber by using bottlebrush through the vent tube openings 9 Replace combustion chamber burner and control Check all gas piping for leaks before lighting heater Repair service should be performed by qualified persons The heater should be inspected before initial use An annual cleaning of control compartment and safety performance check should be made by a qualified ...

Страница 10: ...trol system and any gas control which has been under water LIGHTING INSTRUCTIONS 1 STOP Read the information on the safety label 2 Turn temperature control knob to OFF or it s lowest position 3 Depress and turn gas control knob clockwise to OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the information on the sa...

Страница 11: ...lot 2 Clean burner ports do not enlarge ports 3 Low gas pressure 3 Check gas supply pressure See Gas Supply 4 Pilot decreases in size when main 4 Supply piping is inadequately sized Consult local gas burners come on utility or competent installer 5 Drafts around unit 5 Eliminate drafts 6 Pilot lighter door open causing 6 Close pilot lighter door disturbance of pilot flame 7 Improper venting 7 See ...

Страница 12: ...CHART POOR HEATING RESULTS Cont d Burner won t light 1 Pilot flame too large or too small 1 Re adjust pilot flame using adjustment on combination control valves See Fig 1 1A 2 Defective combination control valve 2 Replace valve Pilot outage 1 Dirt in pilot orifice 1 Clean pilot orifice with air or solvent do not ream 2 Pilot lighter door open 2 Close pilot lighter door 3 Defective automatic pilot ...

Страница 13: ...s provided See figure A STEP6 Connect black wire from junction box to right fan switch terminal See Figure B STEP7 Connect white wire from junction box to white fan motor wire See Figure B STEP8 Connect black wire from fan motor to left fan switch terminal See Figure B STEP9 Turn variable speed control switch clockwise as viewed from front of unit to OFF STEP 10 Plug power cord into 115 V grounded...

Страница 14: ...ll prices are F O B factory NOTICE When ordering any component in the control train assembly specify either Honeywell or Robertshaw components Page 14 50 43 51 47 44 46 53 45 49 42 48 17 16 15 REV 08 01 28c Mr Contractor we only sell parts through our wholesalers but the prices listed are for your convenience For prompt parts service contact the wholesaler from which you purchased your Cozy heater...

Страница 15: ...563 23 60 45563 23 60 47113 30 90 VC Casing Bottom Trim 28b 45074 9 90 45564 12 00 45564 12 00 47114 14 00 VC Casing Center Trim w Clips 28c 45077 8 00 45567 9 90 45567 9 90 47117 12 00 VCR Bezel Assembly 29a N A N A 46060 63 80 46060 63 80 47610 69 10 VCR Upper Front Panel with Insulation 29b N A N A 46035 28 40 46035 28 40 47585 36 40 VCR Lower Front Panel 29c N A N A 46040 25 40 46040 25 40 475...

Страница 16: ...ath IF YOU SMELL GAS DON T LIGHT IT IF YOU CAN T LIGHT IT DON T FIGHT IT THIS IS NOT AN ADVERTISEMENT WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department In...

Страница 17: ...ll request such service directly from the installer If the user is unable to locate the installer the user should write directly to the manufacturer and the name of an alternative service source will be supplied The product safety registration card packed inside the appliance must be completed and returned to the factory THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED...