The control I/O port interfaces the tester to an external device such as PLC with the capabilities to control
and receive the test results remotely. This port allows the tester to be integrated into a fully automated line.
a) Connector type:
Leak tester side: DB-37P (XM2C-3712-112 OMRON or equivalent)
Cable side:
DB-37S (XM2D-3701 OMRON or equivalent)
b) Connector configuration: NO: Normally open NC: Normally closed
PIN#
FUNCTION
TYPE
PIN#
FUNCTION
TYPE
1
Reserved
20
Reserved
2
START
NO, INPUT
21
CH#3
NO, INPUT
3
STOP
NO/NC, INPUT 22
CH#2
NO, INPUT
4
CHARGE HOLD
NO, INPUT
23
CH#1
NO, INPUT
5
Master-Preset
*1
NO, INPUT
24
CH#0
NO, INPUT
6
Reserved
25
Reserved
7
Reserved
26
Reserved
8
Reserved
27
Reserved
9
Reserved
28
Reserved
10
DC Power input
29
Reserved
11
Reserved
30
Reserved
12
Reserved
31
WORK NG (HH-NG)
*3
NO, OUTPUT
13
WORK NG(Hi-NG)
*3
NO, OUTPUT 32
MASTER NG(Lo-NG)
*3
NO, OUTPUT
14
Good
NO, OUTPUT 33
MASTER NG(LL-NG)
*3
NO, OUTPUT
15
Reserved
34
Time extension
*2
NO, OUTPUT
16
ERROR
NO, OUTPUT 35
END (a)
NO, OUTPUT
17
STAGE#1
NO, OUTPUT 36
BUSY
NO, OUTPUT
18
STAGE#0
NO, OUTPUT 37
Reserved
19
COM for all outputs
*1
Master-Preset value sampling
*2
Timer extension signal is transmitted at the Noise Reduction process execution, or the
Master-Preset value sampling.
*3
NG judgement signal is transmitted during DL3 and END stages. Signal output can be limited to
END stage, or change the output to a hold signal by memory switch setting.
HI-NG:
It is output when the tested part limit value HI is exceeded.
HH-NG:
It is output when the HI is exceeded by +10% (NR limit). (At this point, also HI-NG is
output.)
LO-NG:
It is output when the reference part limit value LO is exceeded.
LL-NG:
It is output when the LO is exceeded by +10% (NR limit). (At this point, also LO-NG
is output.)
c) Power supplies
Operational power supplies are required to use the control I/O port.
Rated input voltage: 12 to 24 VDC ±10%, 0.2 A max. (external power supplied by the SELV circuit)
Leave the pins marked “Reserved” in the table above opened.
NOTE
Содержание LS-1866
Страница 2: ......
Страница 6: ......
Страница 22: ......
Страница 34: ......
Страница 56: ......
Страница 62: ......
Страница 71: ...11 INTERFACE 69 g Typical PLC connection NPN h Typical connection with PLC PNP ...
Страница 88: ......
Страница 89: ...13 APPENDIX 87 1 13 3 APPENDIX 1 13 3 1 1 E EX XT TE ER RN NA AL L A AP PP PE EA AR RA AN NC CE E ...