Power Supply
from the
CKL6230N
wiring centre
Max load
5 (2) A
Dimensions [mm]
80 x 80 x 20
CKPL
module extends the functionality of the
CKL6230N
wiring
centre.
The module is used to control the pump using N / E / L contacts.
It helps to save electrical power. Whenever there is no heat demand,
the pump will be unpowered and not wasting any energy.
This product complies with the essential requirements and other
relevant provisions of the following EU Directives: EMC 2014/30/EU,
Low Voltage Directive LVD 2014/35/EU, RoHS directive 2011/65/EU.
Use in accordance to national and EU regulations. Use the device
as intended, keeping it in dry condition. Product for indoor use only.
Installation must be carried out by a qualified person in accordance
to national and EU regulations.
Before any of operation releated to power supply (connecting
wires, installing the device, etc.), make sure that the device is not
connected to any power source. Incorrect connection of the wires
may cause damage to the wiring centre. The module can not be
used in conditions of water vapor condensation neither exposed
to water.
The serial connector from the
CKL6230N
wiring centre provides
communication between the wiring centre and the
CKPL
module.
CKL6230N
wiring
CKPL
module increases functionality
and additionally makes possible to control pump.
CKPL
module is
powered from the wiring centre.
COSMO
GmbH
Brandstücken 31
22549 Hamburg
www.cosmo-info
.de
March 2020
V003
Pump Logic Module
Model:
CKPL
Quick Guide
I N T R O D U C T I O N
S E R I A L C O N N E C T O R F O R
C K P L M O D U L E
P R O D U C T C O M P L I A N C E
S A F E T Y I N F O R M AT I O N
T E C H N I C A L S P E C I F I C AT I O N
T E R M I N A L S D E S C R I P T I O N
fuse
(T10A)
L
N
L
N
L
N
L
N
L
N
L
N
L
N
11
22
33
44
55
66
N
N
N
N
N
N
T E R M I N A L
D E S C R I P T I O N
N
Neutral pin
Earth pin
L
Pump output
Note:
All terminals are screwless, push type.