4 Temperature
Measurement Point
¡
Ambient temperature indicates the temperature of the inlet of the
air.
Ambient temperature
measurement point
Airflow
Fig.4.1 Ambient temperature measurement point
¡
Temperature of Forced air
Use the temperature measurement point as shown in Fig.4.2 to
4.3. Please use at the temperature dose not exceed the values in
Table 4.1. Please also make sure that the ambient temperature
does not exceed 70
C
.
¿
KHEA30F, KHNA30F
POINT C
(T201)
POINT A
(C106)
POINT B
TB2
TB1
(C515)
Fig.4.2 Temperature measurement point (Forced air)
¿
KHEA60F, KHNA60F
POINT C
(T201)
POINT A
(C107)
POINT B
TB2
TB1
(C516)
Fig.4.3 Temperature measurement point (Forced air)
¿
KHEA90F, KHNA90F
POINT A
(C106)
POINT B
TB2
TB1
(C515)
*
*
*
Please be careful of electric shock or earth leakage in case of temperature measurement,
because POINT A and POINT B is live potential.
Fig.4.4 Temperature measurement point (Forced air)
Table 4.1 Specified temperature of the measurement point
No.
Model
Temperature measurement point
Point A
Point B
Point C
1
KHEA30F, KHNA30F
80
C
80
C
105
C
2
KHEA60F, KHNA60F
80
C
80
C
105
C
3
KHEA90F, KHNA90F
80
C
80
C
OUTPUT
CASE
CHASSIS
4- JOINT PART
INPUT
Fig.4.5 Installation removing chassis and case
Thermocouple for temperature checking must be added into tem-
perature measuring point after removing chassis and case.
Then assembling chassis and case again, the temperature can be
measured.
Chassis and case are fixed in 4 parts which are shown in the figure.
Please contact us about detail.
¡
Temperature of Forced air
Use the temperature measurement point as shown in Fig 4.6.
Please use at the temperature does not exceed the values in
Table 4.2.
Please also make sure that the ambient temperature does not ex-
ceed 70
C
.
AC-DC Power Supplies DIN Rail Type
Instruction Manual
KH-25
June 29, 2020