1.12  Derating for low temperature start-up

¡

Derating shown in Table 5.5 is required for low temperature start-
up.

Table 1.4  Derating for low temperature start-up

No.

Model

temperature range Load factor

1

KHEA30F, KHNA30F

-40

C

 to -20

C

50%

2

KHEA60F, KHNA60F

3

KHEA90F, KHNA90F

4

KHEA120F, KHNA120F

-40

C

 to -25

C

75%

5

KHEA240F, KHNA240F

6

KHEA480F, KHNA480F

2  Peak Current

¿ 

KHEA120F/240F/480F, KHNA120F/240F/480F

¡

The units can generate the peak current under the following con-
ditions.

-

t1

[

5sec

-

Ip

[

Rated peak current

-

Iave

[

Rated current

*

Please use a maximum of Duty following shown in Table 2.1.

-

Duty=

     t1     

X

100 [%] 

            

t1+t2

[A]

Output current

Ip : Peak current

Iave : Average current

I : Load current

t1

t2

Fig.2.1  Peak current

Table 2.1  Maximum Duty by the mounting orientation

Mounting

orientation

Input

Voltage

Maximum Duty

KHEA120F
KHNA120F

KHEA240F
KHNA240F

KHEA480F-24
KHNA480F-24

KHEA480F-48
KHNA480F-48

A

AC85 - 170V

35%

35%

20%

20%

AC170 - 264V

15%

B

AC85 - 264V

20%

C

AC85 - 264V

5%

D

AC85 - 264V

20%

E

AC85 - 264V

3 Series/Parallel 

Operation

3.1  Series Operation

¡

You can use a power supply in series operation. The output cur-
rent in series operation should be lower than the rated current of a 
power supply with the lowest rated current among the power sup-
plies that are serially connected. Please make sure that no current 
exceeding the rated current flows into a power supply.

Load

(a)

(b)

Load

Load

Power 

Supply

+

-

Power 

Supply

+

-

Power 

Supply

+

-

+

-

Power 

Supply

Fig.3.1  Examples of connecting in series operation

3.2  Parallel Operation

¡

There is no current balance function.
When operating in parallel, such as diode-OR, please use on the 
output voltage was adjusted enough to balance the current.

  Exceeds the rated output current, the output is shut down.

¡

Redundancy operation is available by wiring as shown below.

I

2

I

1

I

3

-

+

+
-

Load

Power

Supply

Power

Supply

Fig.3.2  Example of connecting in redundancy operation

 

Even a slight difference in output voltage can affect the balance 
between the values of I

1

 and I

2

.

Please make sure that the value of l

does not exceed the rated 

current of a power supply.

l

3

 

[

 rated current value

AC-DC Power Supplies DIN Rail Type

Instruction Manual

KH-24

June 29, 2020

Содержание KHEA120F

Страница 1: ...Signal Output 1 12 Derating for low temperature start up 2 Peak Current KH 24 3 Series Parallel Operation KH 24 4 Temperature Measurement Point KH 25 5 Life Expectancy and Warranty KH 26 6 Applicable...

Страница 2: ...d 1 3 Overcurrent Protection KHEA30F 60F 90F KHNA30F 60F 90F A overcurrent protection circuit is built in and activated over 105 of the rated current A unit automatically recovers when a fault conditi...

Страница 3: ...OFF 1 If the output of an external power supply is within the range of 4 5 29 5V you do not need a current limiting resistor R If the output exceeds 29 5V however please connect the current limit ing...

Страница 4: ...4V 3 Series Parallel Operation 3 1 Series Operation You can use a power supply in series operation The output cur rent in series operation should be lower than the rated current of a power supply with...

Страница 5: ...ement because POINT A and POINT B is live potential Fig 4 4 Temperature measurement point Forced air Table 4 1 Specified temperature of the measurement point No Model Temperature measurement point Poi...

Страница 6: ...B Convection AC85 170V Ta 30C or less 10years or more 8years Ta 40C 10years or more 3years AC170 264V Ta 45C or less 10years or more 7years Ta 55C 5years 3years C Convection AC85 170V Ta 40C or less...

Страница 7: ...Ta 30C 10years or more 8years AC170 264V Ta 40C or less 10years or more 9years Ta 50C 8years 4years A B C D and E Forced air AC85 264V Ta 70C 5years 3years Table 5 6 Life Expectancy KHEA480F KHNA480F...

Страница 8: ...rs 5years Ta 60C 5years 3years AC170 264V Ta 50C or less 5years 5years Ta 60C 5years 4years B Convection AC85 170V Ta 40C or less 5years 5years Ta 50C 5years 5years AC170 264V Ta 40C or less 5years 5y...

Страница 9: ...on 7 1 Outline of option C Option C models have coated internal PCB for better moisture resistance E KHEA90F KHNA90F Option E models acquires NEC Class2 N2 KHEA120F 240F 480F KHNA120F 240F 480F Option...

Отзывы: