© Corroventa Ltd
2017.06
7 (8)
Accessories
When filtering is required, the HP2000XT is designed to be used with the Flexifilter H13, a compact and
lightweight filter unit capable of cleaning large volumes of air. H13 rated, its degree of separation exceeds
99.95% for up to 1080m3 / h. The unit also includes a carbon filter layer for removing bad odours.
Installation
1.
Put the HP 2000XT where it shall be used and connect the hoses, if any, that are to be used for
the air distribution.
2.
Connect the cable to a 1-phase, 230 VAC socket with a 10A or maximum 16A fuse. As the machine
is normally used in humid or wet spaces, the use of a ground fault circuit interrupter is strongly
recommended.
3.
Put the power switch in position On and select fan speed, high or low.
4.
Verify that the correct air flows are achieved.
Fault finding
Symptom
Probable cause
Action
Fan does not start.
Power cable not connected.
Mains power not available.
Check that power cable is connected and
availability of power in the outlet.
Air flow is too low
Counter pressure through
the installation is too big.
Fan is malfunctioning
Adjust the installation to lower the counter
pressure
Contact retailer for repair of the fan.