Us e r Man u al I C MA - 4 82 - A E N I P a g e 2 6
RAU5x+ R RxU67 (MIMO)
Composite 16 AWG Tether Distance (ft.) Draw (Watts)
Composite 16 AWG Tether Distance (ft.)
Draw (Watts)
10
– 100
62
570
– 610
70
110
– 170
63
620
– 660
71
180
– 240
64
670
– 710
72
250
– 320
65
730
– 750
73
330
– 380
66
760
– 790
74
390 - 440
67
800
– 830
75
450 - 510
68
840
– 860
76
520 - 560
69
870 - 900
77
*Min/Max VDC = 37/57@ 1.49 Amps, 85% efficiency
Table 3-6. Remote End Distance and Power Draw for RAU5x + RxU67 (MIMO)
GEM Supporting PoE 802.3af
Composite 16 AWG Tether Distance (ft.)
Draw (Watts)
10 - 40
31
50 - 340
32
350 - 660
33
670 - 890
34
900
35
*Min/Max VDC = 43/57 @ 1.49 Amps, 85% efficiency
Table 3-7. Remote End Distance and Power Draw for GEM w/PoE.3af
GEM Supporting PoE 802.3at
Composite 16 AWG Tether Distance (ft.) Draw (Watts)
Composite 16 AWG Tether Distance (ft.)
Draw (Watts)
10 - 80
64
590 - 620
73
90 - 170
65
630 - 670
74
180 - 230
66
680 - 710
75
240 - 300
67
720
– 750
76
310 - 370
68
760
– 790
77
380 - 420
69
800 - 820
78
430 - 470
70
830 - 850
79
480 - 530
71
860 - 890
80
540 - 580
72
900
81
*Min/Max VDC = 52/57 @ 1.49 Amps, 85% efficiency
Table 3-8. Remote End Distance and Power Draw for GEM w/PoE.3at