1. General

1.1

 

This procedure describes Pretium EDGE                                                                                          

Tap Modules, which are available for both multimode 

and single mode applications. Compatible with all 

Pretium EDGE rack-mountable connector housings, 

TAP modules have twelve front-mounted shuttered 

LC adapters and two MTP

®

 connectors in back          

(Figure 1). 

1.2

 

The module contains 12 fiber optic splitters which divide the incoming optical signals into two 

outputs, one for live link traffic and one for monitoring. The monitor traffic is routed via the “TAP”-labeled 

MTP connector to a monitoring device which filters the data and sends it to various software tools for 

analysis, where it is then viewed in application-layer software for security threats, performance issues, or 

system optimization. 

IMPORTANT:

  Please note that Tap module systems have two outputs for each input, which may 

require two power meters, and depending on the system configuration, possibly require an additional 

craftsperson in another location.

1.4 

If this procedure is reissued, a summary of the changes will appear in this paragraph.

2

1

B

A

1

4

3

B

A

2

6

5

B

A

3

8

7

B

A

4

10

9

B

A

5

12

11

B

A

6

VOID

     

    

    

WAR

RA

NT

Y

Port 

Tap Module

  M

Part Number:

 Serial

   

 MADE IN MEXICO

  US P

ATENT

 NO.  

TAP

LIVE

Figure 1

HPA-0753

related literature  |

SRP-003-794, Pretium EDGE

®

 Solution

SRP-006-136, Multifiber Connector and Port Cleaning with the TKT-CLEAN-MFC-M kit

table of contents  |

1.  General .................................................................................................................................................1
2.  Precautions ...........................................................................................................................................2
3.  Tools and Materials ...............................................................................................................................2
4.  Connector and Adapter Cleaning ..........................................................................................................2
5.  Calculating System Loss .Budgets .......................................................................................................3
6.  The Functionality of the Tap Module Splitters .......................................................................................5
7.  Installing Pretium EDGE Tap Modules ...................................................................................................6
8.  Referencing the Test Equipment for a Tap Module ...............................................................................6
9.  Testing Pretium EDGETap Modules .....................................................................................................8 

 

Содержание Pretium EDGE ETM-5B-Q

Страница 1: ...here it is then viewed in application layer software for security threats performance issues or system optimization IMPORTANT Please note that Tap module systems have two outputs for each input which...

Страница 2: ...not crush the cable or allow it to kink Doing so may cause damage that can alter the transmission characteristics of the cable the cable may have to be replaced 3 Tools and Materials 3 1 The following...

Страница 3: ...omponent Loss max dB 1 Loss max dB 1 MTP mated pair loss 0 35 0 75 LC mated pair loss 0 15 0 5 Splitter 50 50 dB 3 8 3 6 Splitter 30 70 dB 6 6 1 8 6 0 2 0 1 Insertion loss specifications when mated to...

Страница 4: ...depends on length of system B 6 12 11 A B 5 10 9 A B 4 8 7 A B 3 6 Port Tap Module Part Number Serial MADE IN MEXICO TAP LIVE 5 A B 2 4 3 A B 1 2 1 A W A R R A N T Y VOID Tap Module A Pretium EDGE Mod...

Страница 5: ...rce and output positions 6 2 Tap modules therefore must be tested with directionality in mind The source must be always connected to the input of the splitter and the meter must be connected to the ou...

Страница 6: ...the 850 nm wavelength For single mode systems Set the unit to auto switch between 1310 and 1550 nm wavelengths 8 2 To reference the source and two meters Step 1 Clean and insert the SC end of the SC...

Страница 7: ...he LC adapter and protect it with a clean dust cap Step 12 Leave the LC adapter on the end of RJ3 for the remainder of this procedure since it will be required for mating to the TAP port test harness...

Страница 8: ...ctor into the number 1 port of the Pretium Edge module Module B in Figure 11 Step 3 Install LC connector number 1 from the Tap port test harness into the LC adapter on the end of RJ3 Step 4 Save or re...

Страница 9: ...ource LC Position at B Meter no 1 LC Position at A Meter no 2 TAP Port Test Harness B 2 A 1 2 B 4 A 3 4 B 6 A 5 6 B 8 A 7 8 B 10 A 9 10 B 12 A 11 12 Table 3 9 4 To test the odd numbered ports at the f...

Отзывы: