INSTALLATION INSTRUCTIONS 

 

AND 

 

OPERATION MANUAL 

 
 

SGH Series

 

UL325-2010 Compliant

 

Commercial and Industrial Door Operator 

 

Logic Control 

 

Continuous Duty 

 

 

Содержание SGH Series

Страница 1: ...INSTALLATION INSTRUCTIONS AND OPERATION MANUAL SGH Series UL325 2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty ...

Страница 2: ...way from all moving parts of the door 7 Install the Entrapment Warning Placard next to the control station in a prominent location 8 Make sure the available power supply to be connected to the operator is of the same voltage frequency phase and wattage as indicated on the nameplate of the operator 9 Read and understand the wiring diagram of the operator and the control station open close stop push...

Страница 3: ...Speed 6 8 per sec average typical Brake Solenoid actuated brake Emergency Chain Hoist Standard ENTRAPMENT PROTECTION Sensing Edge Optional Sensing device attached to the bottom edge of the door Non Contact Device Optional Photo eye device Per the requirements of UL Standard 325 the door operator is setup for constant pressure to close the door As an alternative the door may be provided with a moni...

Страница 4: ... LS LA Consult factory for changes in installation positions NOTE Any change in mounting position may result in a change of operator rotation and consequently in a change of control functions Consult factory for any changes LH LS and RA RH RS and LA Operators mounted in alternate positions LA RA require the long mounting legs in lieu of the standard short mounting legs ...

Страница 5: ...n installation positions NOTE Any change in mounting position may result in a change of operator rotation and consequently in a change of control functions Consult factory for any changes LH LS and RA RH RS and LA Operators mounted in alternate positions LA RA require a straight mounting plate in lieu of the standard bent plate ...

Страница 6: ...oles on the bracket are correct 3 Bolt the operator mounting plate to the door bracket plate 4 Attached and tighten the three mounting legs to the mounting plate Not applicable for 1hp 1 hp 2hp 5 Finally mount the operator to the three legs and tighten for 1 2 and 3 4hp only For other horsepowers mount the operator to the mounting plate Figure 1 for 1 2hp and 3 4hp Figure 2 for 1hp and 1 hp ...

Страница 7: ...aft 7 The shelf or bracket must provide adequate support for the operator Prevent play between the operator and the door shaft The operator must be securely attached with the drive shaft parallel to the door shaft It may be necessary to field brace the operator bracket Correct Incorrect Door Sprocket Operator Drive Sprocket Figure 1 for 1 2hp and 3 4hp Correct Incorrect Door Sprocket Operator Driv...

Страница 8: ...ator may be used for adjustment See figure 1 S1 location for 1 2hp and 3 4hp See figure 2 T1 T2 T3 T4 for 1hp and 1 hp 2 Once the drive chain has been tightened and the base leg screws have been set and then tighten the operator screws S1 Drive Chain Door Sprocket Drive Sprocket 1 4 S1 Drive Chain Door Sprocket Drive Sprocket 1 4 Figure 1 for 1 2hp and 3 4hp Drive Chain Door Sprocket Drive Sprocke...

Страница 9: ...8 SGH Series REVISION 0002 DATE 10 09 2012 HAND CHAIN ADJUSTMENT Cut and reconnect chain with different color link provided Chain Holder Optional ...

Страница 10: ...lace adjust the limit switch cam E or F until the micro switch C or D clicking sound is heard 5 If the limit switch cam cannot be rotated to its desired position release the lever and move the door away from the desired position then adjust the limit switch cam to its desired position It may be necessary to repeat this step until the exact position has been reached 6 Repeat step 3 and 4 for the op...

Страница 11: ...ted to the control panel must be protected by conduit or other means to ensure the safety and permanency of the wiring 5 Use copper wire inside the control panel 6 A separate circuit of adequate capacity is needed for the operator 7 The operator must be properly grounded The ground screw painted green is located inside the control panel Failure to properly ground the operator could result in elect...

Страница 12: ...t device wiring connections to the operator Sensing Edge Photo Eye 6 max above floor Entrapment Device Options Sensing Module Device Manufacturer Model ELR 2 wire resistive sensing edge Miller Edge Inc End of Line resistor type edge must have model number with Suffix T2 ME110 ME111 ME120 ME123 ME112 ME113 ME116 ME117 MT21 MU21 MT22 MU22 MC22 MU33 MC271 CPT223 MEL ASO GMBH GE125 GE225 IR Monitored ...

Страница 13: ...r wiring 4 Any wire connected to the control panel must be protected by conduit or other means to ensure the safety and permanency of the wiring Do not use radio controls with your operator unless some type of entrapment protection device has been installed Failure to do so may result in serious injury or death to person s trapped beneath the door Changing from left hand to right hand or vice vers...

Страница 14: ...2 3 4 7 8 9 10 23 24 P5 P6 E5 E6 L1 L2 L1 L2 1 Stop 2 Open 3 Close 4 Com 7 8 Close Warning signal 24VAC Single phase power source See operator plate for correct voltage A 1 A 3 1 2 3 4 7 8 9 10 23 24 P5 P6 E5 E6 IR P5 P6 ELR E5 E6 ELR End of line resistor L1 L2 L3 Three phase power source See operator plate for correct voltage A 3 On Momentary Pressure Off Constant Pressure 9 10 External I nterloc...

Страница 15: ...0 09 2012 B Auxiliary Function Open door Stop door Close door R3 R2 R1 R1 R2 R3 Radio control GND Push button 24VDC B B 1 B 2 B 3 1 2 3 4 1 1 2 Close limit dry contact 2 3 4 Open limit dry contact 1 2 1 2 CN12 CN13 CN14 SE 24VDC MAX0 5A ...

Страница 16: ... starts counting when door leaves close limit Door stops after opening for set time Pressing open again at mid open position will cause door to open to open limit Timer 2 Timer to close Timer is active when door stops and is not at close limit Timer 3 Door Open Warning Timer Timer is active when door leaves close limit When time is up contact will close See figure C 1 Timer LED is lit when a value...

Страница 17: ...thout pressing and holding for 5 seconds no adjustment is confirmed SELECT UP SET TIMER RESET DOWN TIMER 1 TIMER 2 TIMER 3 COUNTER 5 Seconds TIMER 1 TIMER 2 TIMER 3 COUNTER SELECT UP SET TIMER RESET DOWN For save Mid Open Timer Set the desired time Press SET until Timer 2 light is lit Continue to set Timer 2 or no action until counter light is lit SELECT UP SET TIMER RESET DOWN TIMER 1 TIMER 2 TIM...

Страница 18: ... TIMER RESET DOWN TIMER 1 TIMER 2 TIMER 3 COUNTER Min 1 Sec Max 99 Sec SELECT UP SET TIMER RESET DOWN TIMER 1 TIMER 2 TIMER 3 COUNTER Min 1 Sec Max 99 Sec 5 To Set Timer 3 Buzzer Timer z Use and to increase or to decrease time z Press and hold for 5 seconds to confirm setting Without pressing and holding for 5 seconds no adjustment is confirmed TIMER 1 TIMER 2 TIMER 3 COUNTER SELECT UP SET TIMER R...

Страница 19: ... TIMER 2 TIMER 3 COUNTER Set Mode Set Mode SELECT UP SET TIMER RESET DOWN TIMER 1 TIMER 2 TIMER 3 COUNTER SELECT UP SET TIMER RESET DOWN TIMER 1 TIMER 2 TIMER 3 COUNTER Set Mode Select Timer Note To enable timer s 1 Must switch Timer Switch to ON See figure A 2 on Page 13 for location 2 Must remove jumper on Terminal PCB CN2 23 24 See figure A 1 on Page 13 for location ...

Страница 20: ...ected with ELR OFF Not connecting or damaged ELR LED8 Device light ON Sefety device disconnected failed or damaged OFF When any one of sensing device is normal LED17 Open button ON Activated OFF Not activated LED18 Close button ON Activated OFF Not activated LED16 Control Station stop ON Connect with 3 button control station and not activate STOP button OFF Not connect with 3 button control statio...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ... ELR sensing edge Stop Open Close Com Close warning signal 24VDC Jump when no external interlock is connected Control panel is wired with momentary pressure open and constant pressure close A one second delay on reverse is standard When the door is closing pushing the Open or Stop button will stop the door from moving When the door is closing the radio control transmitter can stop and reverse the ...

Страница 34: ...After adjusting either the force or the limit of travel retest the door operator s safety features Failure to adjust the operator properly may cause severe injury or death 5 For products having a manual release if possible use the manual release only when the door is closed Use caution when using this release when the door is open Weak or broken springs may cause the door to fall rapidly causing s...

Страница 35: ...o stop movement of the door while opening or closing Removing pressure from the CLOSE key position will cause the door to stop 3 Door may also be operated by remote devices EMERGENCY MANUAL OPERATION This operator has provisions for manually operating the door in case of emergency or power failure This operator is equipped with an auxiliary hoist To operate the hoist 1 Remove the hand chain from t...

Страница 36: ...icate Sprockets Check set screw tightness Fasteners Check tighten as required Bearings Shafts Check for wear lubricate Do not lubricate motor Lubrication could cause damage Inspect and service whenever a malfunction either door or operator is observed or suspected Before servicing always disconnect power supply to the operator Replace fuses only with those of the same type and rating All replaceme...

Страница 37: ...K GR STOP CLOSE OPEN R WH BK B2 OPEN CLOSE NC NO C NC NO C STOP WH WH GR KEY SWITCH 3 1 BUTTON B2 OPEN Key switch B2 COM Warning Remove Jump Pin First See A A Remove Jump pin OPEN CLOSE STOP OPE N CLOSE S T O P S T O P 1 2 3 4 R BK R WH OPEN CLOSE NC NO C NC NO C STOP WH WH GR KEY SWITCH COM OPE N CLOSE S T O P S T O P Key Switch with Stop Button and 3 Button Stations Key Switch with Stop Button C...

Страница 38: ...E OPEN R WH WH WH WH B2 B1 OPEN CLOSE STOP KEY ON OFF OPEN CLOSE STOP KEY LOCKOUT 3 2 BUTTON B1 B2 1 2 3 4 OPEN OPEN CLOSE CLOSE B2 B1 STOP B2 STOP B1 R BK GR KEY LOCKOUT 3 BUTTON 1 2 3 4 OPEN CLOSE STOP Key switch Key switch R WH GR BK STOP CLOSE OPEN ON OFF R2 R1 RADIO R3 R2 R1 Ceiling Pull Switch Station 1 4 1 4 CLOSE OPEN CLOSE OPEN R1 R3 R2 JUMP GR WH 3 2 1 WH BK GR WH BK Control Connections ...