background image

Viper 3 Flavor Plumbing Installation Instructions

© 2008-2017, Cornelius Inc.

- 1 -

Publication Number: 629096928INS

INSTALLATION INSTRUCTIONS

S

AFETY

 I

NSTRUCTIONS

!

WARNING:

Before starting installation, read and understand all safety label and warnings on the machine. Also review and 
understand all safety instructions in the owners, installation and service manuals.

Failure to comply could result in serious injury, death or damage to the equipment.

Q

UALIFIED

 S

ERVICE

 P

ERSONNEL

!

WARNING:

Only trained and certified electrical, plumbing and refrigeration technicians should service this unit.

All wiring and plumbing must conform to national and local codes. Failure to comply 
could result in serious injury, death or equipment damage.

S

AFETY

 P

RECAUTIONS

This unit has been specifically designed to provide protection against personal injury. To ensure continued 
protection observe the following:

!

WARNING:

Disconnect power to the unit before servicing. Follow all lock out/tag out procedures established by the user. Verify 
all power is off to the unit before performing any work.

Failure to comply could result in serious injury, death or damage to the equipment.

!

CAUTION:

Always be sure to keep area around the unit clean and free of clutter.

Failure to keep this area clean may result in injury or equipment damage.

Revision Date: August 23, 2017

 www.cornelius.com

Revision: H

Содержание VIPER 3 FLAVOR

Страница 1: ...it All wiring and plumbing must conform to national and local codes Failure to comply could result in serious injury death or equipment damage SAFETY PRECAUTIONS This unit has been specifically designed to provide protection against personal injury To ensure continued protection observe the following WARNING Disconnect power to the unit before servicing Follow all lock out tag out procedures estab...

Страница 2: ...els extended and locked in the outboard position prior to moving the unit Failure to comply could result in serious injury death or equipment damage Parts List Table 1 Parts List Sl No Part No Description Quantity UOM 1 08859 Tie Cable 11 Std Dennison 10 EA 2 174478000 Tubing Flexcor 265 X 465 500 Ctn 8 FT 3 178025100 Gasket 1 4 Male Flare Fitting 5 EA 4 309852000 Clamp OETR 669 Open Stpls 17 0 10...

Страница 3: ...o consid eration the total potential water demand that may be placed on the store water supply by all equipment within the store Equipment such as fountain dispensers icemakers coffee brewers and juice dispensers typically draw water from a common source filter system The FCB machine must be supplied with water to the specification above at all times even when any of the other equipment is drawing...

Страница 4: ...erage T ubing Inch Beverage T ubing 3 8 Inch T ygon T ubing A B C D E Outlet on Syrup Pump 2 5HJXODWRU 6HFRQGDU Inch Female Flare Nut Direct Connection to Syrup Outlet on Syrup Pump Direct Connection to CO2 Inlet on Syrup Pump Direct Connection to Syrup Direct Connection to Syrup Inlet on Syrup Pump Water Inlet Syrup Line 1 CO2 Inlet BIBSyrup BIBSyrup BIBPump C E D G BIBPump C E D Syrup Line 2 Syr...

Страница 5: ...res a dedicated 3 8 CO2 line with a regulator located at the unit An additional dedicated 3 8 CO2 line is required with a regulator located at the BIB rack Viper 3 Flavor Plumbing Installation Instructions 2008 2017 Cornelius Inc 5 Publication Number 629096928INS Viper CO2 setup Single unit Figure 2 Viper CO2 setup single unit ...

Страница 6: ...g in Box 3 8 Lines 75 1 psig 75 1 psig NOTE Each unit requires a dedicated 3 8 CO 2 line with a regulator located at the unit An additional dedicated 3 8 CO 2 line is required with a regulator located at the BIB rack Viper 3 Flavor Plumbing Installation Instructions Publication Number 629096928INS 6 2008 2017 Cornelius Inc Viper CO2 setup Multiple unit Figure 3 Viper CO2 setup multiple unit ...

Отзывы: