IDC 255 Progate Drive Thru Installation Manual
© 2006, IMI Cornelius Inc.
- 15 -
Publication Number: 621057419INS
The agitation time equals the dispense time multiplied by the agitation ratio. The user is given the
flexibility to change the agitation ratio thereby altering the agitation time in order to ensure that the ice
chute is always filled with ice for all the different ice types.
FIGURE 17
Programming (Changing) the Agitation Time
1.
Simultaneously Press and hold for 3 seconds, the
button and also both direction arrow
buttons
to enter the programming mode.
2.
The LED meter turns ON once the programming mode is entered. Visual feedback of ratio/agitation
time is obtained from the visual programming LED
. The LED meter shows the
existing agitation ratio enabling the user to.
3.
Vary the agitation time using the directional arrow buttons. Left to decrease and right direction
arrow button to increase.
2
10
14
16
18
12
24
20
22
26
28